Answers are grounded in this paper and cite their sources.
Multiple-bit errors caused by single-ion tracks in a 256-kb DRAM fabricated by a bulk process were observed for different ion species and stopping power values. The results demonstrate the utility of this device for the evaluation of ion-beam uniformity and ion-beam-induced charge collection in IC devices. The data indicate that single-ion-induced charge transport results in multiple-bit error clusters due to lateral diffusion of excess minority carriers (electrons). Charge collection occurred from a depth of up to 35 mu m from te surface of the device. An apparent charge loss was observed for very heavy ions with a high stopping power (Au at 350 MeV).>
No takes yet. Share an insight, caveat, or question.
Zoutendyk et al. (1990) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: