Single-Event Upset (SEU) in bipolar integrated circuits (ICs) is caused by charge collection from ion tracks in various regions of a bipolar transistor. This paper presents experimental data which have been obtained wherein the range-energy characteristics of heavy ions (Br) have been utilized to determine the cross section for soft-error generation as a function of charge collected from single-particle tracks which penetrate a bipolar static RAM. The results of this work provide a basis for the experimental verification of circuit-simulation SEU modeling in bipolar ICs.
No takes yet. Share an insight, caveat, or question.
Zoutendyk et al. (1984) studied this question.