Key result
An immunoaffinity chromatography column removed an average of greater than 5 logs of spiked poliovirus type 1 from a protein mixture in a single passage.
Answers are grounded in this paper and cite their sources.
An immunoaffinity chromatography column using human polyclonal antibodies can effectively remove over 5 logs of poliovirus type 1 from protein mixtures, offering a potential viral clearance method for biopharmaceutical manufacturing.
An immunoaffinity matrix was prepared using human polyclonal antibody (Intragam) attached to Sepharose 4B activated with CNBr. The immunoaffinity matrix was then assessed with regard to its capacity to remove viruses. The challenge virus, poliovirus type 1 was loaded in high titre in either PBS or a preparation derived from human plasma known as supernatant II + III. This fraction is depleted of IgG and is used to prepare human albumin. It was shown that an average greater than 5 logs of spiked virus were removed in one passage through the column. This type of approach may prove useful as a viral removal method in biopharmaceutical manufacturing.
No takes yet. Share an insight, caveat, or question.
Cameron‐Smith et al. (2001) studied this question. Immunoaffinity chromatography column was evaluated on Removal of spiked poliovirus type 1 (> 5 logs removal). An immunoaffinity chromatography column removed an average of greater than 5 logs of spiked poliovirus type 1 from a protein mixture in a single passage.