Key result
Post-implant ventricular arrhythmias are not linked to higher mortality in CF-LVAD recipients.
Why the study?
Ventricular arrhythmias are observed in 25% to 50% of continuous-flow left ventricular assist device recipients, but their role on mortality is debated.
Do post-implant ventricular arrhythmias, biventricular pacing percentage, or timing of ICD implantation impact mortality and arrhythmia occurrence in patients with a continuous-flow LVAD?
Cohort (n=69)
No
Do post-implant ventricular arrhythmias, biventricular pacing percentage, or timing of ICD implantation impact mortality and arrhythmia occurrence in patients with a continuous-flow LVAD?
In CF-LVAD recipients with an ICD, post-implant ventricular arrhythmias and timing of ICD implantation do not significantly affect survival, whereas biventricular pacing >=98% is associated with a higher burden of ventricular arrhythmias without impacting mortality.
Answers are grounded in this paper and cite their sources.
Post-implant ventricular arrhythmias do not affect mortality in CF-LVAD recipients; leaves open optimal arrhythmia management strategies.
BACKGROUND: Ventricular arrhythmias (VAs) are observed in 25%-50% of continuous-flow left ventricular assist device (CF-LVAD) recipients, but their role on mortality is debated. METHODS: Sixty-nine consecutive patients with a CF-LVAD were retrospectively analyzed. Study endpoints were death and occurrence of first episode of VAs post CF-LVAD implantation. Early VAs were defined as VAs in the first month after CF-LVAD implantation. RESULTS: During a median follow-up of 29.0 months, 19 patients (27.5%) died and 18 patients (26.1%) experienced VAs. Three patients experienced early VAs, and one of them died. Patients with cardiac resynchronization therapy (CRT-D) showed a trend toward more VAs (p = 0.076), compared to patients without CRT-D; no significant difference in mortality was found between patients with and without CRT-D (p = 0.63). Patients with biventricular (BiV) pacing ≥98% experienced more frequently VAs (p = 0.046), with no difference in mortality (p = 0.56), compared to patients experiencing BiV pacing <98%. There was no difference in mortality among patients with or without VAs after CF-LVAD [5 patients (27.8%) vs. 14 patients (27.5%), p = 0.18)], and patients with or without previous history of VAs (p = 0.95). Also, there was no difference in mortality among patients with a different timing of implant of implantable cardioverter-defibrillator (ICD), before and after CF-LVAD (p = 0.11). CONCLUSIONS: VAs in CF-LVAD are a common clinical problem, but they do not impact mortality. Timing of ICD implantation does not have a significant impact on patients' survival. Patients with BiV pacing ≥98% experienced more frequently VAs.
No takes yet. Share an insight, caveat, or question.
Gulletta et al. (2022) conducted a cohort in Stage D heart failure with reduced ejection fraction treated with continuous-flow left ventricular assist device (CF-LVAD) (n=69). Post-implant ventricular arrhythmias (VAs) in CF-LVAD recipients vs. CF-LVAD recipients without post-implant ventricular arrhythmias was evaluated on All-cause mortality (p=0.18). Post-implant ventricular arrhythmias occurred in 26.1% of CF-LVAD recipients but did not impact mortality compared to those without arrhythmias.
Synapse has enriched 10 related papers. Consider them for comparative context: