Key result
Calculated coronary resistance during reactive hyperemia increased when venous pressure was used as back pressure, but showed little change when zero-flow arterial pressure was used.
Why the study?
Does the choice of back pressure (venous pressure vs zero-flow arterial pressure) affect the calculated coronary vascular resistance during reactive hyperaemia in a canine model?
Does the choice of back pressure (venous pressure vs zero-flow arterial pressure) affect the calculated coronary vascular resistance during reactive hyperaemia in a canine model?
The calculation of coronary vascular resistance during reactive hyperaemia is highly dependent on whether venous pressure or zero-flow arterial pressure is used as the back pressure, suggesting the coronary circulation may act as a collapsible tube.
Answers are grounded in this paper and cite their sources.
Should not inform clinical coronary resistance calculations; leaves open optimal back pressure for modeling human coronary collapse.
A conscious, chronically instrumented canine model was used to investigate resistance changes in the distribution of the circumflex coronary artery as the artery was constricted. Several discrete constrictions were studied at two different levels of flow: resting and peak flow reactive hyperaemia. The resistance of the bed downstream from the constriction was calculated by formulae which defined the coronary back pressure as either venous pressure (Pv) or the arterial pressure at which coronary flow ceased (Pc). When Pv was taken as the back pressure, the resistance of the coronary bed during reactive hyperaemia progressively increased as the upstream artery was constricted. When Pc was taken as the back pressure, calculated coronary resistance for reactive hyperaemia showed little change. It is not known if elastic recoil of coronary resistance vessels, consequent to low poststenotic pressure, could occur to the extent required to be the physical basis for the calculated increase in resistance when Pv is taken to be the back pressure. Use of Pc as the back pressure implies that the coronary circulation contains a segment having the hydraulic characteristics of a collapsible tube.
No takes yet. Share an insight, caveat, or question.
Ronald F. Bellamy (1980) studied Coronary artery constriction. Coronary artery constriction was evaluated on Coronary vascular resistance. Calculated coronary resistance during reactive hyperemia increased when venous pressure was used as back pressure, but showed little change when zero-flow arterial pressure was used.