Key result
Heterotopic implantation of a porcine bioprosthetic heart valve in the descending aorta successfully palliated severe aortic valve insufficiency in a dog, with sustained clinical improvement at 24 months.
Why the study?
Does heterotopic implantation of a porcine bioprosthetic heart valve in the descending aorta improve symptoms and hemodynamics in a dog with severe aortic valve insufficiency?
Case Report (n=1)
Does heterotopic implantation of a porcine bioprosthetic heart valve in the descending aorta improve symptoms and hemodynamics in a dog with severe aortic valve insufficiency?
Heterotopic bioprosthetic heart valve implantation in the descending aorta is feasible and provides substantial palliation for severe aortic valve insufficiency in a canine model.
CASE DESCRIPTION: A 5-year-old male German Shepherd Dog was evaluated because of a 5-month history of progressive lethargy, weight loss, and heart failure. CLINICAL FINDINGS: On physical examination, bounding femoral pulses and systolic and diastolic murmurs were detected. Echocardiography revealed severe aortic valve insufficiency (AVI) and a large vegetative lesion on the aortic valve consistent with aortic valve endocarditis. The AVI velocity profile half-time was 130 milliseconds; the calculated peak systolic pressure gradient across the aortic valve was 64 mm Hg. Left ventricular diameter during diastole was 63.6 mm (predicted range, 40.2 to 42 mm) and during systole was 42.9 mm (predicted range, 25.4 to 27 mm). Systolic, diastolic, and mean arterial blood pressures were 120, 43, and 65 mm Hg, respectively. TREATMENT AND OUTCOME: To palliate severe AVI, the descending aorta was occluded (duration, 16.75 minutes) and heterotopic implantation of a porcine bioprosthetic heart valve in that vessel was performed. After surgery, systolic, diastolic, and mean arterial blood pressures were 115, 30, and 61 mm Hg, respectively, in the forelimb and 110, 62, and 77 mm Hg, respectively, in the hind limb. Within 6 months, the AVI velocity profile half-time had increased to 210 milliseconds, indicating diminished severity of AVI. After 24 months, the dog was able to engage in vigorous exercise; no pulmonary edema had developed since surgery. CLINICAL RELEVANCE: Heterotopic bioprosthetic heart valve implantation into the descending aorta during brief aortic occlusion appears feasible in dogs and may provide substantial palliation for dogs with severe AVI.
No takes yet. Share an insight, caveat, or question.
Arai et al. (2007) conducted a case report in Aortic valve endocarditis and severe aortic valve insufficiency (n=1). Heterotopic implantation of a porcine bioprosthetic heart valve in the descending aorta was evaluated on Palliation of severe aortic valve insufficiency (clinical improvement, blood pressure, AVI velocity profile half-time). Heterotopic implantation of a porcine bioprosthetic heart valve in the descending aorta successfully palliated severe aortic valve insufficiency in a dog, with sustained clinical improvement at 24 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: