Key result
Patients with congenitally corrected transposition of the great arteries had lower coronary flow reserve compared to healthy controls.
Why the study?
Is myocardial blood flow and coronary flow reserve impaired in unoperated patients with congenitally corrected transposition of the great arteries compared to healthy controls?
Cross-Sectional (n=26)
No
Is myocardial blood flow and coronary flow reserve impaired in unoperated patients with congenitally corrected transposition of the great arteries compared to healthy controls?
Patients with congenitally corrected transposition of the great arteries have impaired coronary flow reserve even in the absence of ischaemic symptoms, suggesting microcirculatory dysfunction.
Answers are grounded in this paper and cite their sources.
Impaired CFR in asymptomatic ccTGA suggests microcirculatory dysfunction; hypothesis-generating and should not yet change practice.
OBJECTIVES: To investigate myocardial blood flow of the morphological right systemic ventricle in unoperated patients with congenitally corrected transposition of the great arteries (CCTGA) by positron emission tomography (PET). DESIGN: Prospective cross sectional clinical study. SETTING: Tertiary referral centre for paediatric cardiology. PATIENTS: 15 patients with CCTGA were investigated by PET with nitrogen-13 ammonia at rest and during adenosine vasodilatation. A subgroup of seven patients had isolated CCTGA (group A, mean (SD) age 30.3 (11.9) years) and the remaining eight patients had complex CCTGA associated with subpulmonary stenosis; four of this second group also had ventricular septal defect (group B, mean (SD) age 30.6 (16.4) years). Eleven healthy adults (mean (SD) age 26.2 (5.1) years) served as the control group. RESULTS: Resting myocardial blood flow was not different between both groups of patients with CCTGA and the controls. Hyperaemic blood flows were significantly lower in both groups of CCTGA than in the control group (mean (SD) 195 (21) ml/100g/min in group A, 201 (27) ml/100g/min in group B, 309 (74) ml/100g/min in the control group; p < 0.001). Thus, coronary flow reserve was significantly lower in both groups of CCTGA than in the control group (mean (SD) 2.5 (0.28) in group A, 2.6 (0.48) in group B, and 4.0 (0.73) in the control group; p < 0.001). CONCLUSION: Blood flow measurements suggest that coronary reserve is decreased in the absence of ischaemic symptoms in patients with CCTGA. The global impairment of stress flow dynamics may indicate altered global vasoreactivity, and quantitative changes in microcirculation suggest that their role in the pathogenesis of systemic right ventricular dysfunction is important.
No takes yet. Share an insight, caveat, or question.
M. Häuser (2003) conducted a cross-sectional in Congenitally corrected transposition of the great arteries (n=26). Congenitally corrected transposition of the great arteries vs. Healthy adults was evaluated on Coronary flow reserve (p=< 0.001). Patients with congenitally corrected transposition of the great arteries had lower coronary flow reserve compared to healthy controls.
Synapse has enriched 10 related papers. Consider them for comparative context: