Key result
3D-CT guidance for left atrial appendage occlusion significantly improved 1st device selection accuracy compared to 2D-TEE (92% vs 27%, P=0.01).
Why the study?
Does 3D-CT guidance improve device selection accuracy and procedural efficiency compared to 2D-TEE in patients undergoing LAAO?
RCT (n=24)
randomized
No
Does 3D-CT guidance improve device selection accuracy and procedural efficiency compared to 2D-TEE in patients undergoing LAAO?
Absolute Event Rate: 92% vs 27%
p-value: p=.01
3D-CT guidance for LAAO significantly improves first-device selection accuracy and procedural efficiency compared to standard 2D-TEE.
3D-CT guidance may enhance LAAO first-device success; extends RCT evidence for optimized imaging selection.
BACKGROUND: Preliminary data comparing 3-dimensional computed tomography (3D-CT) to transesophageal echocardiography (TEE) for left atrial appendage occlusion (LAAO) indicates that 3D-CT provides more accurate measurements and improves case planning. Therefore, we conducted a pilot study comparing 3D-CT to TEE in occluder selection accuracy and procedural efficiency. METHODS: From May 2016 to February 2017, 24 patients were prospectively randomized to undergo LAAO using either TEE or 3D-CT. The primary endpoint was device accuracy while the secondary endpoints included # devices per case, # guide catheters used per case, # fluoroscopy angles used, procedure time, fluoroscopy time, radiation dose, and major adverse events (stroke, MI, device embolization, perforation, death). RESULTS: Procedure success was 100% and 92% for the 3D-CT and 2D-TEE cohorts respectively. Accuracy for 1st device selection 92% and 27% (P = .01) for 3D-CT and 2D-TEE respectively but with intra-procedural upsizing in the 2D-TEE cohort, the 2D-TEE cohort accuracy increased to 64% while the 3D-CT groups 92% was accurate (P = .33). Case planning using 3D-CT was significantly more efficient with respect to device utilization (CT 1.33 ± 0.7 vs. 2D-TEE 2.5 ± 1.2 P = .01), guide catheters (CT 1 vs. 2D-TEE 1.7 ± 0.8 P = .01) and procedure time (3D-CT 55 ± 17 min vs. 2D-TEE 73 ± 24 min P < .05). One major adverse event, a stroke occurred in the 2D-TEE group. CONCLUSION: In this single-center pilot study, CT guided LAAO case planning was associated with improved device selection accuracy and procedural efficiency. This study data supports the notion that comprehensive 3D assessment significantly simplifies LAAO, minimizing the time and number of steps needed.
No takes yet. Share an insight, caveat, or question.
Eng et al. (2018) conducted an RCT in left atrial appendage occlusion (n=24). 3-dimensional computed tomography (3D-CT) guidance vs. Transesophageal echocardiography (2D-TEE) guidance was evaluated on device accuracy (1st device selection) (p=.01). 3D-CT guidance for left atrial appendage occlusion significantly improved 1st device selection accuracy compared to 2D-TEE (92% vs 27%, P=0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: