Key result
Spin-lock MRI signal suppression was reduced by 8%-70% in LGMD patients compared to healthy volunteers, demonstrating an inverse correlation with symptom duration.
Why the study?
Can spin-lock MRI quantify microstructural changes in calf muscles of patients with limb girdle muscular dystrophy compared to healthy volunteers?
Observational (n=15)
Can spin-lock MRI quantify microstructural changes in calf muscles of patients with limb girdle muscular dystrophy compared to healthy volunteers?
Spin-lock MRI can quantify microstructural changes in LGMD, providing information on tissue integrity that is not obtainable from standard clinical evaluations.
Answers are grounded in this paper and cite their sources.
Spin-lock MRI may quantify LGMD muscle integrity beyond standard evaluation; leaves open prospective validation for monitoring or trials.
Spin-lock imaging is a new magnetic resonance imaging (MRI) technique used to reflect the microstructural integrity of muscle. The purpose of this study was to characterize spin-lock contrast (SLC) of calf muscles in limb girdle muscular dystrophy (LGMD). The calf muscles of 5 patients with LGMD and 10 healthy volunteers were imaged with an off-resonance magnetic resonance (MR) spin-lock suppression pulse. Spin-lock suppression ratios were calculated for anterior tibialis, posterior tibialis, soleus, and gastrocnemius muscles. Clinical assessments of muscle strength were compared to the spin-lock suppression ratios in the LGMD group. Strong SLC was observed in healthy muscles, with mean (+/- SD) suppression ratios ranging from 51.2% (+/- 3.6%) to 56.3% (+/- 1.3%). In diseased muscle, spin-lock signal suppression was reduced by 8%-70%, demonstrating an inverse correlation between symptom duration and suppression ratios. Spin-lock contrast in the patients with LGMD, as a reflection of tissue integrity, was best preserved in posterior tibialis, anterior tibialis, soleus, and gastrocnemius muscles in descending order. Clinical assessments did a poorer job of differentiating than SLC did and were in poor agreement with spin-lock suppression ratios. Spin-lock MRI can quantify microstructural changes in LGMD and appears to provide information not obtainable from clinical evaluations. This suggests that this noninvasive technique may be useful in evaluating the extent, progression, and response to therapy of LGMD.
No takes yet. Share an insight, caveat, or question.
Franczak et al. (2000) conducted an observational in Limb girdle muscular dystrophy (n=15). Spin-lock magnetic resonance imaging vs. Healthy volunteers was evaluated on Spin-lock suppression ratios. Spin-lock MRI signal suppression was reduced by 8%-70% in LGMD patients compared to healthy volunteers, demonstrating an inverse correlation with symptom duration.
Synapse has enriched 10 related papers. Consider them for comparative context: