Key result
Lower body negative pressure mimics hemodynamic stimulus-response trajectories of blood loss, with the CVP-MAP slope being the only CVP-response difference.
Why the study?
Does lower body negative pressure elicit similar hemodynamic and blood analyte responses compared to graded blood loss in men?
Does lower body negative pressure elicit similar hemodynamic and blood analyte responses compared to graded blood loss in men?
Lower body negative pressure is a valid experimental model that largely mimics the hemodynamic stimulus-response trajectories of actual blood loss in humans.
Answers are grounded in this paper and cite their sources.
LBNP largely replicates blood loss hemodynamics in healthy men; leaves open validation for clinical translation or broader populations.
The purpose of this study was to compare hemodynamic and blood analyte responses to reduced central venous pressure (CVP) and pulse pressure (PP) elicited during graded lower body negative pressure (LBNP) to those observed during graded blood loss (BL) in conscious humans. We hypothesized that the stimulus-response relationships of CVP and PP to hemodynamic responses during LBNP would mimic those observed during BL. We assessed CVP, PP, heart rate, mean arterial pressure (MAP), and other hemodynamic markers in 12 men during LBNP and BL. Blood samples were obtained for analysis of catecholamines, hematocrit, hemoglobin, arginine vasopressin, and blood gases. LBNP consisted of 5-min stages at 0, 15, 30, and 45 mmHg of suction. BL consisted of 5 min at baseline and following three stages of 333 ml of hemorrhage (1,000 ml total). Individual r(2) values and linear regression slopes were calculated to determine whether the stimulus (CVP and PP)-hemodynamic response trajectories were similar between protocols. The CVP-MAP trajectory was the only CVP-response slope that was statistically different during LBNP compared with BL (0.93 ± 0.27 vs. 0.13 ± 0.26; P = 0.037). The PP-heart rate trajectory was the only PP-response slope that was statistically different during LBNP compared with BL (-1.85 ± 0.45 vs. -0.46 ± 0.27; P = 0.024). Norepinephrine, hematocrit, and hemoglobin were all lower at termination in the BL protocol compared with LBNP (P < 0.05). Consistent with our hypothesis, LBNP mimics the hemodynamic stimulus-response trajectories observed during BL across a significant range of CVP in humans.
No takes yet. Share an insight, caveat, or question.
Johnson et al. (2014) studied this question. Lower body negative pressure (LBNP) vs. Blood loss (BL) (1,000 ml total) was evaluated on CVP-MAP trajectory slope (p=0.037). Lower body negative pressure mimics hemodynamic stimulus-response trajectories of blood loss, with the CVP-MAP slope being the only CVP-response difference.
Synapse has enriched 10 related papers. Consider them for comparative context: