Key result
Premature beats with shorter S1S2 coupling intervals significantly increased early total repolarization time dispersion from 1.0 to 2.3 ms/mm (P<0.0001) in patients with cardiomyopathy.
Observational (n=7)
Absolute Event Rate: 2.3% vs 1%
p-value: p=< 0.0001
In high-risk patients with cardiomyopathy, tightly coupled premature beats increase total repolarization time dispersion due to activation-repolarization uncoupling, potentially predisposing to reentrant ventricular arrhythmias.
Suggests tightly coupled premature beats may increase ventricular arrhythmia risk in cardiomyopathy; leaves open whether targeting this.
Premature beats can trigger ventricular arrhythmias in heart disease, but the mechanisms are not well defined. We studied the effect of premature beats on activation and repolarization dispersion in seven patients with cardiomyopathy (57 ± 10 yr, left ventricular ejection fraction 31 ± 7%). Activation time (AT), activation-recovery interval (ARI), and total repolarization time (TRT) were measured from 26 unipolar electrograms during right ventricle (RV) endocardial (early) to left ventricle epicardial (late) activation in response to RV apical extrastimulation (S1S2). Early TRT dispersion increased significantly with shorter S1S2 (1.0 ± 0.2 to 2.3 ± 0.4 ms/mm, P < 0.0001), with minimal change in late TRT dispersion (0.8 ± 0.1 to 1.0 ± 0.3 ms, P = 0.02). This was associated with an increase in early AT dispersion (1.0 ± 0.1 to 1.5 ± 0.2 ms/mm, P = 0.05) but no change in late AT dispersion (0.6 ± 0.1 to 0.7 ± 0.2 ms/mm, P = 0.4). Early and late ARI dispersion did not change with shorter S1S2. AT restitution slopes were similar between early and late sites, as was slope heterogeneity. ARI restitution slope was greater in early vs. late sites (1.3 ± 0.6 vs. 0.8 ± 0.6, P = 0.03), but slope heterogeneity was similar. With shorter S1S2, AT-ARI slopes became less negative (flattened) at both early (-0.4 ± 0.1 to +0.04 ± 0.2) and late (-1.5 ± 0.2 to +0.3 ± 0.2) sites, implying less activation-repolarization coupling. There was no difference in AT-ARI slopes between early and late sites at short S1S2. In conclusion, high-risk patients with cardiomyopathy have greater TRT dispersion at tightly coupled S1S2 due to greater AT dispersion and activation-repolarization uncoupling. Modulated dispersion is more pronounced at early vs. late activated sites, which may predispose to reentrant ventricular arrhythmias.
No takes yet. Share an insight, caveat, or question.
Subramanian et al. (2011) conducted an observational in Cardiomyopathy at risk of sudden death (n=7). Premature beats (shorter S1S2 extrastimulation) vs. Longer S1S2 extrastimulation (baseline) was evaluated on Early total repolarization time (TRT) dispersion (p=< 0.0001). Premature beats with shorter S1S2 coupling intervals significantly increased early total repolarization time dispersion from 1.0 to 2.3 ms/mm (P<0.0001) in patients with cardiomyopathy.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: