Key result
A novel catheter torque tool decreased muscle activation in 4 of 6 muscle groups and improved perceived workload during simulated cardiac ablation, without altering task completion time or attempts.
Why the study?
Cardiac ablation catheters present ergonomic challenges requiring significant finger dexterity and strength, which can affect catheter stability.
Does a novel catheter torque tool reduce muscle activation and improve perceived workload in cardiology attendings and fellows performing simulated cardiac ablation?
RCT
Semi-randomized order
Does a novel catheter torque tool reduce muscle activation and improve perceived workload in cardiology attendings and fellows performing simulated cardiac ablation?
A novel catheter torque tool reduces muscle fatigue and perceived workload during simulated cardiac ablation, potentially improving procedural safety and catheter stability.
Answers are grounded in this paper and cite their sources.
May reduce operator fatigue in simulated ablation; leaves open effects on real-world stability or safety.
Background: Cardiac ablation catheters are small in diameter and pose ergonomic challenges that can affect catheter stability. Significant finger dexterity and strength are necessary to maneuver them safely. We evaluated a novel torque tool to reduce muscle activation when manipulating catheters and improve perceived workload of ablation tasks. The objective was to evaluate measurable success, user perception of workload, and muscle usage when completing a simulated ablation task with and without the use of a catheter torque tool. Methods: Cardiology attendings and fellows were fitted with surface electromyographic (EMG) sensors on 6 key muscle groups in the left hand and forearm. A standard ablation catheter was inserted into a pediatric cardiac ablation simulator and subjects navigated the catheter tip to 6 specific electrophysiologic targets, including a 1-min simulated radiofrequency ablation lesion. Time to complete the task, number of attempts required to complete the lesion, and EMG activity normalized to percentage of maximum voluntary contraction were collected throughout the task. The task was completed 4 times, twice with and twice without the torque tool, in semi-randomized order. A NASA Task Load Index survey was completed by the participant at the conclusion of each task. Results: Time to complete the task and number of attempts to create a lesion were not altered by the tool. Subjectively, participants reported a significant decrease in physical demand, effort, and frustration, and a significant increase in performance. Muscle activation was decreased in 4 of 6 muscle groups. Conclusion: The catheter torque tool may improve the perceived workload of cardiac ablation procedures and reduce muscle fatigue caused by manipulating catheters. This may result in improved catheter stability and increased procedural safety
No takes yet. Share an insight, caveat, or question.
Mass et al. (2022) conducted an RCT in Simulated cardiac ablation. Catheter torque tool vs. Without the torque tool was evaluated on Time to complete the task, number of attempts to create a lesion, and muscle activation (EMG activity). A novel catheter torque tool decreased muscle activation in 4 of 6 muscle groups and improved perceived workload during simulated cardiac ablation, without altering task completion time or attempts.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: