Key result
Human and porcine aortic valves had similar average circumferences, but differed in cusp dimensions, with the largest surface area in the human non-coronary cusp.
Observational (n=24)
Significant anatomical differences exist between human and porcine aortic valves regarding cusp size and coaptation points, highlighting the importance of geometric considerations when using porcine valves for transplantation.
Answers are grounded in this paper and cite their sources.
Porcine valves may need geometric adjustments for human use; leaves open functional outcomes in xenotransplantation.
We compared the anatomy of human and porcine aortic valves. Porcine hearts were collected from the abattoir. Human hearts from patients who had died of non-cardiac causes were examined in the mortuary; only undamaged and anatomically normal hearts were used. Silicon casts were prepared by injecting engineering silicon at 80 mm Hg into the aortic arch. Various features of the aortic valve were measured: circumference, length between the commissural end point and central point of coaptation, surface diameter, and surface area. In total, 12 porcine and 12 human aortic valves were studied. The average circumferences of the human and porcine aortic valves were 8.00 +/- 0.2 (SD) cm and 7.90 +/- 1.0 cm, respectively. The central point of coaptation in human valves was skewed toward the left coronary cusp, whereas in porcine valves it was skewed toward the non-coronary cusp. In human aortic valves, the non-coronary cusp had the largest surface diameter and surface area with mean measurements of 3.6 +/- 0.2 cm and 1.230 +/- 0.228 cm(2), respectively; the left coronary cusp was smallest for the same variables with measurements of 3.1 +/- 0.3 cm and 0.898 +/- 0.357 cm(2). In porcine valves, the right coronary cusp had the largest surface diameter and surface area with mean measurements of 3.9 +/- 0.7 cm and 1.716 +/- 0.81 cm(2), respectively; the non-coronary cusp was the smallest for the same variables with measurements of 2.9 +/- 0.5 cm and 1.023 +/- 0.659 cm(2). These differences suggest that when using porcine valves as transplant material (e.g., stentless valves), geometric considerations, such as commissural length, may be important.
No takes yet. Share an insight, caveat, or question.
Sim et al. (2003) reported an observational. Human aortic valves vs. Porcine aortic valves was evaluated on Aortic valve circumference and cusp dimensions. Human and porcine aortic valves had similar average circumferences, but differed in cusp dimensions, with the largest surface area in the human non-coronary cusp.
Synapse has enriched 10 related papers. Consider them for comparative context: