Key result
Medtronic Freestyle stentless aortic bioprostheses were associated with lower mid-term prosthetic valve calcification or sclerosis compared to stented bioprostheses.
Why the study?
Do Medtronic Freestyle stentless aortic bioprostheses improve outcomes compared to stented aortic bioprostheses in end-stage renal disease patients on regular haemodialysis requiring AVR?
Cohort (n=84)
Do Medtronic Freestyle stentless aortic bioprostheses improve outcomes compared to stented aortic bioprostheses in end-stage renal disease patients on regular haemodialysis requiring AVR?
Answers are grounded in this paper and cite their sources.
In haemodialysis patients requiring AVR, Medtronic Freestyle stentless bioprostheses offer lower postoperative gradients and reduced mid-term valve calcification compared to stented bioprostheses, with similar survival.
OBJECTIVES: End-stage renal disease patients on regular haemodialysis are at higher risk of calcification. Therefore, many surgeons have concerns regarding the implantation of bioprostheses in such patients. The haemodynamic advantages of stentless aortic bioprostheses support their use; however, these have not been studied yet in end-stage renal disease patients. We studied accordingly the early and mid-term outcomes of aortic valve replacement (AVR) using Medtronic Freestyle stentless aortic bioprostheses in this subset of patients in comparison with stented aortic bioprostheses. METHODS: We retrospectively studied two groups of consecutive patients on regular haemodialysis who required AVR between 2007 and 2013. Non-Freestyle (NFS) group received stented aortic bioprostheses (36 patients) and Freestyle (FS) group received Medtronic Freestyle aortic bioprostheses (48 patients). Follow-up ranged from 2 to 76 months with a mean follow-up of 36.3 ± 25 months. RESULTS: Patients in both groups showed similar demographic characters regarding age (76.4 ± 8.1 vs 74.9 ± 7.2 years; P = 0.35), male gender (58 vs 60%; P = 0.57) and diabetes mellitus (42 vs 48%; P = 0.57). Smaller aortic bioprostheses were implanted in the NFS (23.3 ± 1.2 vs 25.4 ± 2.1; P < 0.001) with consequently higher postoperative mean gradients (14.1 ± 4.1 vs 11.9 ± 5.3 mmHg; P = 0.004). No significant differences were noted regarding postoperative neurological disorder (8 vs 12%; P = 0.73), deep sternal wound infection (3 vs 4%; P = 0.68), re-exploration (8 vs 8%; P = 0.91) and in-hospital mortality (6 vs 4%; P = 0.92). Mid-term follow-up showed higher prosthetic valve calcification and/or sclerosis in NFS group (25 vs 6%; P = 0.015), whereas no significant differences were noticed between the two groups regarding stroke (0 vs 8%; P = 0.13), endocarditis (0 vs 4%; P = 0.50), 36- and 72-month survival (51 ± 2%, 14 ± 4% vs 55 ± 2%, 19 ± 3%, respectively; P = 0.45). CONCLUSIONS: Aortic bioprostheses are a good option for haemodialysis patients requiring AVR, offering acceptable mid-term survival. The Medtronic Freestyle aortic bioprostheses could allow the implantation of larger bioprostheses inferring consequently lower mean gradients, with a potentially higher resistance to calcification and sclerosis in haemodialysis patients.
No takes yet. Share an insight, caveat, or question.
Hegazy et al. (2016) conducted a cohort in End-stage renal disease on regular haemodialysis requiring aortic valve replacement (n=84). Medtronic Freestyle stentless aortic bioprostheses vs. Stented aortic bioprostheses was evaluated on Prosthetic valve calcification and/or sclerosis (p=0.015). Medtronic Freestyle stentless aortic bioprostheses were associated with lower mid-term prosthetic valve calcification or sclerosis compared to stented bioprostheses.
Synapse has enriched 10 related papers. Consider them for comparative context: