Key result
Temperature-controlled cooled-tip radiofrequency linear ablation guided by a realtime position management system successfully created a transmural linear ablation line without thrombus in 4 of 9 pigs.
Why the study?
Does temperature-controlled cooled-tip radiofrequency linear ablation guided by a realtime position management system create transmural linear lesions without thrombus formation in a porcine model?
Does temperature-controlled cooled-tip radiofrequency linear ablation guided by a realtime position management system create transmural linear lesions without thrombus formation in a porcine model?
Temperature-controlled cooled-tip RF linear ablation guided by a realtime position management system demonstrates potential for creating transmural linear lesions in the atria without thrombus formation in a porcine model.
Answers are grounded in this paper and cite their sources.
May support further preclinical testing; hypothesis-generating for human AF ablation and should not change practice.
Due to the difficulty in producing a transmural linear lesion and the possibility of complications such as thrombus formation leading to thromboembolism, the catheter-based maze procedure remains problematic. We tested, in pigs, the possibility of using a temperature-controlled cooled-tip radiofrequency (RF) ablation system together with a realtime position management (RPM) system to create a transmural linear lesion uncomplicated by thrombus formation.Nine pigs underwent insertion of two electrode catheters (each with two ultrasound electrodes), one into the coronary sinus (CS) and one into the right ventricular apex (references for ultrasound-based non-fluoroscopic three-dimensional mapping). A cooled-tip catheter (with two ultrasound electrodes) was introduced into the right atrium. Linear right atrial ablation was performed with a custom radiofrequency (RF) generator. The catheter was perfused with 0.66 mL/second of saline. RF was delivered for 60 seconds at a target temperature of 40°C. A linear ablation line was created between the superior vena cava and inferior vena cava. Three-dimensional isochronal maps were created during CS pacing before and after ablation. In 4 of the 9 pigs, a transmural linear ablation line was confirmed by three-dimensional mapping and postmortem macroscopic examination. No endocardial thrombus formation was noted. Temperature-controlled cooled-tip RF linear ablation guided by an RPM system appears to have potential for creating linear lesions in the atria. Further studies are needed to determine whether such an ablation technique and the parameters used will facilitate successful completion of the catheter-based maze procedure.
No takes yet. Share an insight, caveat, or question.
Watanabe et al. (2011) studied Atrial fibrillation (experimental model) (n=9). Temperature-controlled cooled-tip radiofrequency linear ablation guided by RPM was evaluated on Creation of a transmural linear ablation line (grade 1 lesion). Temperature-controlled cooled-tip radiofrequency linear ablation guided by a realtime position management system successfully created a transmural linear ablation line without thrombus in 4 of 9 pigs.
Synapse has enriched 10 related papers. Consider them for comparative context: