Key result
During oxygen-fentanyl anesthesia, patients with poor left ventricular function were less likely to develop hypertension than those with good function.
Why the study?
Does oxygen-fentanyl anesthesia elicit different hemodynamic responses in patients with poor versus good left ventricular function undergoing aortocoronary bypass surgery?
Cohort (n=19)
Does oxygen-fentanyl anesthesia elicit different hemodynamic responses in patients with poor versus good left ventricular function undergoing aortocoronary bypass surgery?
Patients with poor left ventricular function exhibit a blunted hypertensive response during fentanyl anesthesia induction for bypass surgery due to insufficient myocardial reserve, despite similar anesthetic plasma concentrations.
Answers are grounded in this paper and cite their sources.
Lower hypertension rates in poor LV function during fentanyl may signal limited reserve; leaves open function-stratified induction protocols for bypass surgery.
Seven patients with poor left ventricular function (LVF) defined as ejection fraction less than 0.3, left ventricular end-diastolic pressure equal to or greater than 20 ton, and at least one area of myocardial dyskinesia, and 12 patients with good LVF scheduled for aortocoronary bypass surgery were anesthetized with a loading dose of 30 μg/kg fentanyl followed by infusion of fentanyl at a rate of 0.3 μg/kg/min until the start of rewarming on cardiopulmonary bypass. Premedication consisted of 0.15 mg/kg of diazepam orally and 0.15 mg/kg of morphine and 0.4 mg of scopolamine intramuscularly. Hemodynamic studies were obtained before and after induction and also after intubation, skin incision, sternotomy, and aortic dissection. Blood samples were taken for fentanyl radioimmunoassay before induction of anesthesia and 5, 10, 20, and 30 min after induction, and every 30 min thereafter. There were no significant differences in plasma fentanyl concentrations in the two groups. However, all patients with good LVF, as compared with only three of seven patients with poor LVF, became hypertensive. A significant number of patients (P < 0.05) with poor LVF did not develop hypertension because they appeared to have insufficient myocardial reserve to allow them to increase cardiac index in the face of an increase in systemic vascular resistance. We conclude that the study patients with both poor and good LVF anesthetized with a fentanyl infusion technique show similar plasma concentrations of fentanyl. We further conclude that such patients respond differently during induction of anesthesia and initial surgery and that this difference is a function of myocardial reserve rather than depth of anesthesia.
No takes yet. Share an insight, caveat, or question.
Wynands et al. (1983) conducted a cohort in Aortocoronary bypass surgery (n=19). Poor left ventricular function vs. Good left ventricular function was evaluated on Development of hypertension (p=< 0.05). During oxygen-fentanyl anesthesia, patients with poor left ventricular function were less likely to develop hypertension than those with good function.
Synapse has enriched 10 related papers. Consider them for comparative context: