Answers are grounded in this paper and cite their sources.
Purpose: To develop a simple, sensitive and rapid reverse phase HPLC method for the simultaneous analysis of metoprolol succinate and hydrochlorothiazide in a solid dosage form. Methods: The drugs were analysed by a reverse phase C-18 column using 50mM di-sodium hydrogen phosphate:methanol:acetonitrile in a ratio of 525:225:250 as mobile phase. The flow rate was 1 ml/min and the compounds were detected by a UV-detector at 222 nm at a column temperature of 24 ± 2 ºC. The method was statistically validated for linearity and accuracy. Results: The retention time and drug content of metoprolol succinate and hydrochlorothiazide were 5.38 min, 96.05 % and 3.04 min., 97.64 %, respectively. Conclusion: The study shows that the developed method is simple and accurate and that it would be suitable for the simultaneous determination of metoprolol succinate and hydrochlorothiazide in pharmaceutical formulations.
No takes yet. Share an insight, caveat, or question.
Brijesh et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: