Key result
Speckle-tracking echocardiography demonstrated significantly impaired global peak systolic strain in heart transplant recipients with early rejection (-10.52%) compared to those without rejection (-17.54%, p=0.0012).
Why the study?
Does speckle-tracking echocardiography accurately detect subclinical heart transplant rejection in heart transplant recipients?
Observational (n=117)
No
Does speckle-tracking echocardiography accurately detect subclinical heart transplant rejection in heart transplant recipients?
Absolute Event Rate: -10.52% vs -17.54%
p-value: p=0.0012
Speckle-tracking echocardiography, specifically global longitudinal peak systolic strain, can serve as an early non-invasive diagnostic criterion for subclinical heart transplant rejection.
Strain imaging may enable earlier noninvasive rejection monitoring after transplant; hypothesis-generating and needs prospective validation.
Aim . To identify new predictors of heart transplant rejection by using speckle-tracking echocardiography technique. Materials and methods. 117 recipients were included into research. The follow-up period in S.V. Ochapovsky Region Clinical Hospital No 1 was from March 2010 to April 2015. The groups were allocated based on results of the retrospective analysis of biopsies: group 1 (n = 68), recipients without signs of cellular and humoral rejection (AMR0 ACR0); group 2 (n = 28), recipients with ACR1; group 3 (n = 16), patients with ACR2; group 4 (n = 5), patients with chronic rejection. The analysis of the results was carried out with endomyocardial biopsy, coronary angiography, transthoracic echocardiography (TTE), tissue Doppler imaging, speckle-tracking echocardiography. Results. Early complications include infections and rejection of heart transplant. Cellular rejection is diagnosed in 70% of cases, humoral rejection in 30% of cases. The disease of coronary arteries is a kind of late complications. It was diagnosed in 13.7%. Fraction rejection sensitivity was 63%, specificity was 97% in recipients with ACR1 while carrying out TTE for the purpose of identification of early diagnostic criterion of rejection; recipients with ACR2 had 75% and 96%, respectively. While carrying out PW sensitivity and specificity Е/А in recipients with ACR1 were 83% and 53%, respectively; recipients with ACR2 had 85% and 52%, respectively. While carrying out PW-TDI sensitivity and specificity Е in recipients with ACR1 were 83% and 58%, respectively; recipients with ACR2 had 88% and 60%, respectively. The assessment of myocardial deformation of the left ventricle is as follows: global peak systolic strain in recipients without rejection (GLPS LV) – (–17.54 ± 3.71%), р = 0.0012; recipients with (ACR1, AMR1) had GLPS LV (–10.52 ± 1.8%), p = 0.0012; recipients with ACR2 had (–6.44 ± 1.8%), p = 0.002; recipients with chronic rejection had (–9.43 ± 1.8%), p = 0.002. The STE GLPS LV parameter (–10.52 ± 1.8%), p = 0.0012, which estimates longitudinal function of myocardium can be considered as early diagnostic criterion of myocardium rejection. The correlation coefficient between CD 3, CD 20, CD 68 and parameter GLPS LV% for groups ACR1-ACR2 was 0.54, 0.86 and 0.26, respectively. Conclusions . The parameters of deformation and cardiac mechanics being estimated by means of speckle-tracking echocardiography can be used as diagnostic monitoring of recipients with rejection of heart transplant.
No takes yet. Share an insight, caveat, or question.
Stavenchuk et al. (2016) conducted an observational in Heart transplant rejection (n=117). Speckle-tracking echocardiography (GLPS LV) vs. Recipients without rejection was evaluated on Global peak systolic strain (GLPS LV) (p=0.0012). Speckle-tracking echocardiography demonstrated significantly impaired global peak systolic strain in heart transplant recipients with early rejection (-10.52%) compared to those without rejection (-17.54%, p=0.0012).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: