Key result
Coronary flow reserve measured by contrast-enhanced transesophageal Doppler echocardiography was lower in patients with type 2 diabetes compared to controls.
Why the study?
Does contrast-enhanced transesophageal Doppler echocardiography measurement of coronary sinus flow reserve detect microvascular dysfunction in patients with type 2 diabetes mellitus?
Observational (n=29)
Does contrast-enhanced transesophageal Doppler echocardiography measurement of coronary sinus flow reserve detect microvascular dysfunction in patients with type 2 diabetes mellitus?
Contrast-enhanced transesophageal Doppler echocardiography measurement of coronary sinus flow reserve can noninvasively detect diabetic microvascular dysfunction.
Answers are grounded in this paper and cite their sources.
Supports noninvasive CFR assessment for diabetic microvascular dysfunction; hypothesis-generating and should not yet change practice.
BACKGROUND: This study was undertaken to investigate whether coronary flow reserve (CFR) using coronary sinus flow (CSF), which can be measured by transesophageal Doppler echocardiography (TEDE), especially when contrast enhanced, is useful in evaluating microvascular dysfunction in patients with diabetes mellitus (DM). METHODS AND RESULTS: CSF recordings using contrast enhanced TEDE were performed before and after adenosine triphosphate infusion (0.15 mg x kg(-1) x min(-1)) in 16 patients with type 2 DM and diabetic retinopathy and in 13 non-DM patients (control). Coronary angiography revealed normal epicardial coronary arteries. CFR was defined as the ratio of the antegrade flow velocity time integral in hyperemic conditions and basal levels. Clear envelopes of CSF were obtained in all DM patients using contrast-enhanced TEDE. CFR using CSF in the DM group was significantly decreased compared with the control group (1.4+/-0.4 vs 2.1+/-0.5, p<0.01), but there were no significant differences of age, ejection fraction, rate of hypertension and hypercholesterolemia between the 2 groups. Using 1.7 of CFR as the cut-off value, diabetic microvascular dysfunction could be detected with 82% sensitivity and 83% specificity. CONCLUSIONS: CFR calculated by CSF using contrast-enhanced TEDE may be useful for evaluating diabetic microvascular dysfunction.
No takes yet. Share an insight, caveat, or question.
Nishino et al. (2006) conducted an observational in Type 2 diabetes mellitus (n=29). Type 2 diabetes mellitus vs. Non-diabetic controls was evaluated on Coronary flow reserve (CFR) (p=<0.01). Coronary flow reserve measured by contrast-enhanced transesophageal Doppler echocardiography was lower in patients with type 2 diabetes compared to controls.
Synapse has enriched 10 related papers. Consider them for comparative context: