Key result
High frame rate Doppler echocardiography provided accurate non-invasive measurements of cardiac structure and function in rats, correlating well with transit time measurements.
Why the study?
Does high frame rate Doppler echocardiography provide accurate measurements of cardiac structure and function compared to transit time and M-mode measurements in normal rats?
Does high frame rate Doppler echocardiography provide accurate measurements of cardiac structure and function compared to transit time and M-mode measurements in normal rats?
Answers are grounded in this paper and cite their sources.
High frame rate Doppler echocardiography provides accurate non-invasive measurements of cardiac structure and function in a rat model.
AIMS: In small animal models, two-dimensional (2D) and Doppler echocardiography should provide more information than M-mode, especially in animals with infarcted and distorted left ventricles, but has been limited by low frame rates and poor near field resolution. New, high frame rate echo-Doppler equipment with digital processing was tested for accuracy of measurements. METHODS AND RESULTS: Fourteen normal Wistar rats (232-328 g) were examined under halothane anaesthesia. Pulsed Doppler recordings from both left ventricular outflow tract(LVOT) and right ventricular outflow tract (RVOT) cor-responded well with simultaneous ultrasound transit time measurements of aortic flow (LVOT: v=0.99x+4.8, min R=0.93. Standard error of estimate (SEE)=8.3 ml x min(-1), and RVOT: v=0.97x -4.3. R=0.93. SEE =8.4 ml x min(-1). No systematic differences were observed over a flow range of 20-90 ml x min(-1). Left ventricular (LV) dimensions assessed by 2D parasternal long-axis and short-axis views were equal to M-mode measurements with LV diameter 6.6 + 0.44 mm, anterior wall 1.8 +/- 0.18 mm, and posterior wall 1.5 + 0.56 mm. Mean absolute difference 4.4-8.5%. Intra- and interobserver variability was 4.6 +/- 4.1% and 6.7 +/- 7.0% for Doppler measurements, and 4.3 +/- 3.8% and 3.8 +/- 4.6% for dimensions, respectively. CONCLUSION: High frame rate Doppler echocardiography provides accurate non-invasive measurements of cardiac structure and function in the rat.
No takes yet. Share an insight, caveat, or question.
Reidar Bjørnerheim (2001) studied Normal Wistar rats (n=14). High frame rate Doppler echocardiography vs. Ultrasound transit time measurements and M-mode echocardiography was evaluated on Accuracy of aortic flow measurements compared to ultrasound transit time (R=0.93). High frame rate Doppler echocardiography provided accurate non-invasive measurements of cardiac structure and function in rats, correlating well with transit time measurements.