Key result
Modified MRV and RVOT echocardiographic views strongly correlate with RV mass at necropsy in rats.
Modified MRV and RVOT echocardiographic views can provide detailed assessment of the right ventricle in rodent models, correlating with necropsy findings.
Answers are grounded in this paper and cite their sources.
Supports modified RV views for rodent phenotyping; leaves open translation to clinical echocardiography.
Echocardiography plays a major role in assessing cardiac function in animal models. We investigated use of a modified parasternal mid right-ventricular (MRV) and right ventricle (RV) outflow (RVOT) view, in assessing RV size and function, and the suitability of advanced 2D-strain analysis. 15 WKY rats were examined using transthoracic echocardiography. The left heart was assessed using standard short and long axis views. For the right ventricle a MRV and RVOT view were used to measure RV chamber and free wall area. 2D-strain analysis was applied to both ventricles using off-line analysis. RV chamber volume was determined by injection of 2% agarose gel, and RV free wall dissected and weighed. Echocardiography measurement was correlated with necropsy findings. The RV mid-ventricular dimension (R1) was 0.42±0.07cm and the right ventricular outflow tract dimension (R2) was 0.34±0.06cm, chamber end-diastolic area measurements were 0.38±0.09cm2 and 0.29±0.08cm2 for MRV and RVOT views respectively. RVOT and MRV chamber area correlated with gel mass. Doppler RV stroke volume was 0.32±0.08ml, cardiac output (CO) 110±27 ml.min-1 and RV free wall contractility assessed using 2D-strain analysis was demonstrated. We have shown that modified MRV and RVOT views can provide detailed assessment of the RV in rodents, with 2D-strain analysis of the RV free wall potentially feasible.
No takes yet. Share an insight, caveat, or question.
Bernardo et al. (2017) studied Normal cardiac function (animal model) (n=15). Modified mid-right ventricular (MRV) and right ventricular outflow tract (RVOT) echocardiographic views vs. Necropsy findings was evaluated on Correlation of echocardiographic RV chamber area with necropsy agarose gel mass (R=0.78 (MRV) and R=0.72 (RVOT), p=0.03 (MRV) and 0.02 (RVOT)). Modified mid-right ventricular and right ventricular outflow tract echocardiographic views provided chamber area measurements that significantly correlated with right ventricular gel mass at necropsy in rats.
Synapse has enriched 10 related papers. Consider them for comparative context: