Key result
A method based on spline interpolation and nonlinear regression successfully separated and selectively averaged QRS complexes, revealing that both amplitude and shape are influenced by respiration.
Answers are grounded in this paper and cite their sources.
A novel spline interpolation and nonlinear regression method improves magnetocardiography by accounting for respiration-induced variations in QRS amplitude and shape.
In magnetocardiography, averaging of QRS complexes is often used to improve the signal-to-noise ratio. However, averaging of QRS complexes ignores the variation in amplitude and shape of the signals caused, for example, by respiration. This may lead to suppression of signal portions within the QRS complexes. Furthermore, for inverse source, reconstructions of dipoles and of current density distributions errors in the spacial arrangement may occur. To overcome these problems we developed a method for separating and selective averaging QRS complexes with different shapes and amplitudes. The method is based on a spline interpolation of the QRS complex averaged by a standard procedure. This spline function then is fitted to each QRS complex in the raw data by means of nonlinear regression (Levenberg-Marquardt method). Five regression parameters are applied: a linear amplitude scaling, two parameters describing the baseline drift, a time scaling parameter, and a time shift parameter. We found that both amplitude and shape of the QRS complex are influenced by respiration. The baseline shows a weaker influence of the respiration. The regression parameters of two neighboring measurement channels correlate linearly. Thus, selective averaging of a larger number of sensors can be performed simultaneously.
No takes yet. Share an insight, caveat, or question.
Huck et al. (2000) studied this question. Method for separating and selective averaging QRS complexes based on spline interpolation and nonlinear regression vs. Standard averaging procedure was evaluated on Separation and selective averaging of QRS complexes with different shapes and amplitudes. A method based on spline interpolation and nonlinear regression successfully separated and selectively averaged QRS complexes, revealing that both amplitude and shape are influenced by respiration.
Synapse has enriched 10 related papers. Consider them for comparative context: