Key result
A new nonlinear rate adaptive algorithm for QT pacemakers achieved a considerable gain in speed of response to exercise compared to the current algorithm.
Why the study?
Does a new nonlinear rate adaptive algorithm improve the initial response of the pacing rate to exercise in patients with implanted QT pacemakers?
Does a new nonlinear rate adaptive algorithm improve the initial response of the pacing rate to exercise in patients with implanted QT pacemakers?
A new nonlinear rate adaptive algorithm for QT pacemakers improves the speed of pacing rate response to physical exercise.
Answers are grounded in this paper and cite their sources.
May enhance initial exercise response in QT-paced patients; hypothesis-generating and requires validation before practice change.
The QT pacemaker is a rate modulated pacemaker that uses the evoked QT interval as an indicator to determine its optimal pacing rate. Despite the generally favorable clinical results with this form of pacing, some flaws in the system have been reported, such as the frequently observed rather slow initial response of the pacing rate to physical exercise, and the phenomenon of oscillation of the heart rate. These problems can be attributed to the rate adaptive algorithm used in the current QT pacemaker. Recently, in a reexamination of the relationship between evoked QT interval and pacing rate, a curvilinear relationship between these parameters has been demonstrated. As a result, a new algorithm has been developed for the next generation of the QT pacemaker. Before this new algorithm was implemented in new implantable devices, it was evaluated in a multicenter clinical investigation, with emphasis on the initial response of the pacing rate to exercise. This study was carried out by means of special software in the programmer of the QT pacemaker. By employing real-time bidirectional telemetry, it was possible to submit the study population, consisting of 37 patients with implanted QT pacemakers of the current generation, to identical exercise tests. Comparing these exercise tests, it appears that a considerable gain in speed of response to exercise can be achieved by using the same sensor with a faster reacting, nonlinear rate adaptive algorithm.
No takes yet. Share an insight, caveat, or question.
Heijer et al. (1989) studied Implanted QT pacemakers (n=37). New nonlinear rate adaptive algorithm vs. Current rate adaptive algorithm was evaluated on Initial response of the pacing rate to exercise. A new nonlinear rate adaptive algorithm for QT pacemakers achieved a considerable gain in speed of response to exercise compared to the current algorithm.