Key result
Laser lead extraction was not associated with a significant increase in tricuspid valve regurgitation, with 88.3% of patients experiencing no significant change in valve function.
Why the study?
Does laser lead extraction increase the incidence of tricuspid valve regurgitation in patients with implanted cardiac leads?
Observational (n=103)
No
Does laser lead extraction increase the incidence of tricuspid valve regurgitation in patients with implanted cardiac leads?
Answers are grounded in this paper and cite their sources.
Laser lead extraction is not associated with a significant increase in the incidence of tricuspid valve regurgitation.
OBJECTIVES: The objective of this study was to examine the effect of laser lead extraction (LLE) on the development of post-procedural tricuspid regurgitation (TR). Some reports have suggested an increase in TR associated with LLE. We present a series of patients who underwent both, LLE and complete echocardiographic evaluation for TR. METHODS: A single centre analysis of consecutive patients referred for LLE between January 2012 and August 2015. One hundred and three patients had tricuspid valve function evaluated before the procedure with a transthoracic echocardiography (TTE), during the procedure using transoesophageal echocardiography and postoperatively using a TTE. TR was graded from 0 (none) to 4 (severe). RESULTS: We treated 235 leads in 103 patients, including 118 ventricular leads. Seventy-seven were male (74.8%) and 26 female (25.2%), with a mean age of 65.6 ± 15.4 years. Mean time from initial lead implantation was 98.0 ± 67.3 months. Twenty-one patients (20.4%) had ejection fraction below 30%. No intra-procedural worsening of tricuspid valve function was seen with TEE in any of the patients. Ten patients (9.7%) were found to have TR before LLE that returned to normal valve function after the procedure. Two patients (1.9%) experienced mild TR after the procedure (both with tricuspid valve endocarditis). Ninety-one patients (88.3%) did not experience any significant change of the tricuspid valve function after LLE. CONCLUSION: Transthoracic and transoesophageal echocardiography findings showed that laser lead extraction was not associated with a significant increase in the incidence of tricuspid valve regurgitation.
No takes yet. Share an insight, caveat, or question.
Pecha et al. (2017) conducted an observational in Patients referred for laser lead extraction (n=103). Laser lead extraction was evaluated on Development of post-procedural tricuspid regurgitation (TR). Laser lead extraction was not associated with a significant increase in tricuspid valve regurgitation, with 88.3% of patients experiencing no significant change in valve function.
Synapse has enriched 10 related papers. Consider them for comparative context: