Key result
Inhalation of 100% oxygen led to an exponential decrease in microembolic signal counts in 42 of 43 patients with baseline counts ≥10, suggesting nitrogen bubbles as the embolic material.
Why the study?
Does 100% oxygen ventilation reduce Doppler microemboli signals in patients with artificial heart valves?
Does 100% oxygen ventilation reduce Doppler microemboli signals in patients with artificial heart valves?
The exponential reduction of microembolic signals during 100% oxygen inhalation suggests that nitrogen bubbles are the underlying embolic material in patients with prosthetic valves.
Answers are grounded in this paper and cite their sources.
May indicate nitrogen bubbles as embolic source in prosthetic valves; leaves open whether oxygen alters clinical events.
BACKGROUND AND PURPOSE: The purpose of this study was to evaluate the influence of inhalation of 100% oxygen on microembolic signal (MES) counts in patients with artificial cardiac valves. METHODS: A total of 134 outpatients were examined. Transcranial Doppler baseline monitoring (45-minute duration) was performed in all patients under resting conditions. The first 30 patients subsequently underwent transcranial Doppler monitoring for at least 20 minutes under noninvasive positive pressure ventilation with 100% oxygen and for an additional 30 minutes under resting conditions. The same protocol was applied to all following patients with a baseline MES count > or = 10, while the examination was discontinued in the remaining patients. RESULTS: Baseline MES counts < 10, which remained unchanged during oxygen inhalation and the subsequent resting period, were observed in 26 of 30 initial patients. A total of 46 patients with MES counts > or = 10 were identified. Oxygen application was feasible in 43 patients. An exponential MES decrease was noted in 42 patients during oxygen inhalation (statistically significant in 38 patients), followed by a subsequent increase in 38 of 43 patients (statistically significant in 25 patients) under resting conditions. CONCLUSIONS: The exponential reduction of MES counts observed in this study corresponds to blood denitrogenation, thus strongly arguing for nitrogen bubbles as underlying embolic material in prosthetic valve carriers.
No takes yet. Share an insight, caveat, or question.
Georgiadis et al. (1997) studied Artificial cardiac valves (n=134). 100% oxygen inhalation vs. Resting conditions was evaluated on Microembolic signal (MES) counts. Inhalation of 100% oxygen led to an exponential decrease in microembolic signal counts in 42 of 43 patients with baseline counts ≥10, suggesting nitrogen bubbles as the embolic material.