Key result
Planned angiographic follow-up after unprotected left main stenting was associated with similar major cardiovascular events rates compared to clinical follow-up, but higher TLR and lower mortality.
Why the study?
Does planned angiographic follow-up reduce MACE in patients with unprotected left main stem stenosis treated with second generation drug-eluting stents?
Cohort (n=440)
Yes
Does planned angiographic follow-up reduce MACE in patients with unprotected left main stem stenosis treated with second generation drug-eluting stents?
Planned angiographic follow-up after unprotected left main stenting is associated with increased target lesion revascularization but may reduce mortality compared to clinical follow-up alone.
Answers are grounded in this paper and cite their sources.
No MACE benefit with planned angiographic follow-up after left main stenting; leaves open possible mortality association in observational data.
BACKGROUND: The value of angiographic follow-up in unprotected left main (ULM) stenting remains undefined. METHODS: The FAILS-2 registry included consecutive patients presenting with a critical lesion of an ULM treated with second generation drug eluting stents in 6 centers from June 2007 to January 2015. Patients were stratified into two groups: those discharged with planned angiographic follow-up and those with clinical follow-up. MACE (Major Adverse Clinical Events, a composite end point of death, myocardial infarction, TLR, and ST) was the primary end point, while each component was a secondary endpoint Sensitivity analysis was performed for patients treated with a provisional or a two-stent strategy. A propensity score analysis was used to compare the outcomes in the two groups. RESULTS: After multivariate adjustment, 220 patients per group were selected. Planned angiographic follow up was performed after a median of 7 (6-10) months. After 16 (14-21) months, rates of MACE were similar between the two groups (24 vs. 21%, P = 0.29) with lower rates of all cause and cardiovascular death in the angiographic control group (6 vs. 14%, P = 0.01 and 3 vs. 6%, P = 0.04) but with higher rates of TLR (15 vs. 5%, P < 0.001). The same trend was seen irrespective of the stent strategy. CONCLUSION: planned angiographic control results in more TLR but may reduce mortality. These findings need to be confirmed by adequately powered randomized controlled trial.
No takes yet. Share an insight, caveat, or question.
D’Ascenzo et al. (2017) conducted a cohort in Unprotected left main stem stenosis (n=440). Planned angiographic follow-up vs. Clinical follow-up was evaluated on MACE (composite of death, myocardial infarction, TLR, and ST) (p=0.29). Planned angiographic follow-up after unprotected left main stenting was associated with similar major cardiovascular events rates compared to clinical follow-up, but higher TLR and lower mortality.