Key result
Endo-aortic clamping demonstrated equivalent myocardial preservation compared to trans-thoracic clamping in right mini-thoracotomy mitral valve surgery, with no significant difference in peak post-operative cardiac troponin T levels (1016.8 vs 1187.0 ng/L, p=0.1071).
Why the study?
Concerns have been raised regarding the adequacy of myocardial protection during right mini-thoracotomy mitral valve surgery, particularly when using endo-aortic clamping.
Does endo-aortic clamping compared to trans-thoracic clamping improve myocardial protection in patients undergoing right mini-thoracotomy mitral valve surgery?
Observational (n=117)
No
Does endo-aortic clamping compared to trans-thoracic clamping improve myocardial protection in patients undergoing right mini-thoracotomy mitral valve surgery?
Absolute Event Rate: 1016.8% vs 1187%
p-value: p=0.1071
Endo-aortic clamping provides equivalent myocardial protection compared to trans-thoracic clamping in patients undergoing right mini-thoracotomy mitral valve surgery, with significantly lower peak CK-MB levels.
Supports equivalent myocardial preservation with endo-aortic clamping; hypothesis-generating pending randomized trials in mini-thoracotomy mitral surgery.
Background:Perfusion strategies and aortic clamping techniques for right mini-thoracotomy mitral valve (MV) surgery have evolved over time and remarkable short- and long-term results have been reported. However, some concerns have raised about the adequacy of myocardial protection during the minimally invasive approach, particularly with the endo-aortic clamp (EAC). Aim of this study was to compare the efficacy, in terms of myocardial preservation, of the EAC with the trans-thoracic aortic clamp (TTC) in patients undergoing right mini-thoracotomy MV surgery. Methods:A single center, prospective observational study was performed on patients undergoing right mini-thoracotomy MV surgery with retrograde arterial perfusion and EAC or TTC. A propensity matched analysis was performed to compare the two groups. Primary outcome was the comparison between cardiac troponin T levels measured at different time-points after surgery. Results:Eighty EAC patients were compared with 37 TTC patients. No cases of myocardial infarction or low cardiac-output syndrome were overall reported. No differences were recorded in terms of stroke, peri-operative mortality, and in the release of myocardial markers, lactates levels and need for inotropic support at different time-points after surgery. CK-MB peak levels were significantly lower in the EAC group. Conclusion:Despite concerns arising about the EAC, this prospective study shows equivalence in terms of myocardial preservation of the EAC compared with the TTC in patients undergoing right mini-thoracotomy MV surgery.
No takes yet. Share an insight, caveat, or question.
Barbero et al. (2021) conducted an observational in Mitral valve regurgitation (n=117). Endo-aortic clamp (EAC) vs. Trans-thoracic aortic clamp (TTC) was evaluated on Peak cardiac troponin T (cTn-T) levels after surgery (p=0.1071). Endo-aortic clamping demonstrated equivalent myocardial preservation compared to trans-thoracic clamping in right mini-thoracotomy mitral valve surgery, with no significant difference in peak post-operative cardiac troponin T levels (1016.8 vs 1187.0 ng/L, p=0.1071).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: