Key result
Right ventricular apex pacing in an isolated human heart demonstrated intraventricular dyssynchrony (125 msec delay) and interventricular dyssynchrony (180 msec delay) on MRI.
Why the study?
Does MRI assessment detect pacing-induced ventricular dyssynchrony during right ventricular apex pacing in an isolated human heart?
Does MRI assessment detect pacing-induced ventricular dyssynchrony during right ventricular apex pacing in an isolated human heart?
MRI can effectively assess pacing-induced intra- and interventricular dyssynchrony in an isolated human heart model, supporting the need for more physiological pacing.
MRI detects RV pacing dyssynchrony ex vivo; leaves open in vivo applicability and clinical pacing implications.
This study demonstrates the capabilities of MRI in the assessment of cardiac pacing induced ventricular dyssynchrony, and the findings support the need for employing more physiological pacing. A human donor heart deemed non-viable for transplantation, was reanimated using an MR compatible, four-chamber working perfusion system. The heart was imaged using a 1.5T MR scanner while being paced from the right ventricular apex (RVA) via an epicardial placed lead. Four-chamber, short-axis, and tagged short-axis cines were acquired in order to track wall motion and intramyocardial strain during pacing. The results of this study revealed that the activation patterns of the left ventricle (LV) during RVA pacing demonstrated intraventricular dyssynchrony; as the left ventricular mechanical activation proceeded from the septum and anterior wall to the lateral wall, with the posterior wall being activated last. As such, the time difference to peak contraction between the septum and lateral wall was approximately 125 msec. Likewise, interventricular dyssynchrony was demonstrated from the four-chamber cine as the time difference between the peak LV and RV free wall motion was 180 msec. With the ongoing development of MR safe and MR compatible pacing systems, we can expect MRI to be added to the list of imaging modalities used to optimize cardiac resynchronization therapy (CRT) and/or alternate site pacing.
No takes yet. Share an insight, caveat, or question.
Eggen et al. (2010) studied Ventricular dyssynchrony (n=1). Right ventricular apex (RVA) pacing was evaluated on Ventricular dyssynchrony (time difference to peak contraction). Right ventricular apex pacing in an isolated human heart demonstrated intraventricular dyssynchrony (125 msec delay) and interventricular dyssynchrony (180 msec delay) on MRI.