Key result
Environmental exposure to lead and cadmium was associated with decreased left ventricular systolic function, with global longitudinal strain decreasing by 0.392% per doubling of blood lead (P=0.034).
Why the study?
Does environmental exposure to lead and cadmium reduce left ventricular function in a general population cohort?
Cohort (n=179)
Does environmental exposure to lead and cadmium reduce left ventricular function in a general population cohort?
Effect estimate: Estimate -0.392% per doubling of exposure
p-value: p=0.034
Environmental exposure to lead and cadmium is associated with subclinical left ventricular systolic dysfunction, suggesting a potential environmental risk factor for heart failure.
May link environmental metals to subclinical LV dysfunction; leaves open causal role and need for prospective trials before clinical adoption.
Background Experimental studies have demonstrated that lead and cadmium have direct toxic effects on the myocardium, but the few human studies are limited by design, assessment of exposure, and use of heart failure as a late‐stage endpoint. Methods and Results In a prospective population study, we studied the association of left ventricular ( LV ) function with blood lead (BPb) and 24‐hour urinary cadmium (UCd). In 179 participants randomly recruited from a Flemish population (50.3% women; mean age 39.1 years), geometric mean BP b and UC d at enrollment (1985‐2000) were 0.20 μmol/L and 6.1 nmol, respectively. We assessed systolic and diastolic LV function 11.9 years (median) later (2005‐2010) by using Doppler imaging of the transmitral blood flow and the mitral annular movement and speckle tracking. In multivariable‐adjusted linear regression, LV systolic function decreased with BP b. For a doubling of exposure, estimates were −0.392% for global longitudinal strain ( P =0.034), −0.618% and −0.113 s −1 for regional longitudinal strain ( P =0.028) and strain rate ( P =0.008), and −0.056 s −1 for regional radial strain rate ( P =0.050). Regional longitudinal strain rate (−0.066 s −1 , P =0.009) and regional radial strain (−2.848%, P =0.015) also decreased with UC d. Models including both exposure indexes did not allow differentiating whether LV dysfunction was predominately related to BP b or UC d. Diastolic LV function was not associated with BP b or UC d ( P ≥0.159). Conclusions Although effect sizes were small, our results suggest that environmental exposure to lead, cadmium, or both might be a risk factor for systolic LV dysfunction, a condition often proceeding to heart failure.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2017) conducted a cohort in General population (n=179). Environmental exposure to lead and cadmium was evaluated on Left ventricular systolic function (global longitudinal strain) (Estimate -0.392% per doubling of exposure, p=0.034). Environmental exposure to lead and cadmium was associated with decreased left ventricular systolic function, with global longitudinal strain decreasing by 0.392% per doubling of blood lead (P=0.034).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: