Key result
Left atrial appendage angiography measured greater usable LAA depth compared to TEE 90°, providing valuable information for Watchman implantation.
Why the study?
Does left atrial appendage angiography provide greater usable LAA depth compared to transesophageal echocardiography in patients undergoing Watchman device implantation?
Observational (n=75)
Does left atrial appendage angiography provide greater usable LAA depth compared to transesophageal echocardiography in patients undergoing Watchman device implantation?
LAA angiography provides greater usable depth information than TEE, which may be particularly valuable for patients deemed to have insufficient depth by TEE alone for Watchman implantation.
Answers are grounded in this paper and cite their sources.
LAA angiography may identify Watchman candidates missed by TEE depth criteria; leaves open whether routine use improves outcomes.
OBJECTIVES: To compare left atrial appendage (LAA) angiography to transesophageal echocardiography (TEE) for assessing usable LAA depth. BACKGROUND: TEE is typically employed for procedural measurement of LAA ostial diameter and depth. Since angiography enhances distal LAA anatomy, we sought to compare angiography to TEE for determining usable LAA depth. METHODS: Seventy five Watchman device cases were retrospectively evaluated. Two independent cardiologists measured intraoperative LAA ostial diameter and depth at standard 0°, 45°, 90°, and 135° TEE omniplane views and in the right anterior oblique (RAO) 30°, caudal (CAUD) 30° angiographic view. RESULTS: VASc score were 74 (±7.2) years and 4.6 (±1.3), respectively. The average ostial diameter and depth (mm) by TEE were 0°: 19.6 and 26.5; 45°: 17.5 and 26.6; 90°: 18.3 and 25.1; 135°: 19.5 and 23.3. The ostial diameter and depth (mm) by RAO 30° CAUD 30° angiography were 21.1 and 29.7. This angiographic view corresponds to a TEE view between 90° and 135°. In comparison to angiography, TEE 90° underestimated the LAA ostial diameter by 2.9 ± 3.7 mm (P < 0.001) and by 1.9 ± 4.0 mm at TEE 135° (P < 0.01); Pearson's r 0.53 angiography/TEE 90° and 0.50 angiography/TEE 135°. More importantly, TEE 90° underestimated the true usable LAA depth by 5.4 ± 5.8 mm (P < 0.001) and by 7.3 ± 6.1 mm at TEE 135° (P < 0.001); Pearson's r 0.39 angiography/TEE 90° and 0.30 angiography/TEE 135°. CONCLUSIONS: Compared to TEE, LAA angiography provides additional depth information and may be particularly valuable when patients have insufficient depth for Watchman by TEE measures.
No takes yet. Share an insight, caveat, or question.
Glassy et al. (2018) conducted an observational in Left atrial appendage occlusion (n=75). Left atrial appendage angiography vs. Transesophageal echocardiography (TEE) was evaluated on Usable LAA depth (MD 5.4, p=<0.001). Left atrial appendage angiography measured greater usable LAA depth compared to TEE 90°, providing valuable information for Watchman implantation.
Synapse has enriched 10 related papers. Consider them for comparative context: