Why the study?
How do different pacing modes (VVI vs DDD) and AV delays affect ANP and c-AMP levels during rest and exercise in patients with complete heart block?
How do different pacing modes (VVI vs DDD) and AV delays affect ANP and c-AMP levels during rest and exercise in patients with complete heart block?
Adrenergic activity and ANP release during exercise appear lower in DDD pacing with a shorter AV delay (100 ms) compared to a longer AV delay (150 ms) or VVI pacing.
Answers are grounded in this paper and cite their sources.
VVI pacing may raise resting ANP versus DDD at 150 ms AV delay; hypothesis-generating for mode selection in complete heart block.
Nine patients (three males) mean age 68 +/- 8 years, having complete heart block, and paced in the DDD mode were examined in VVI and DDD pacing with 100 and 150 ms atrioventricular delays (AVD) during rest and exercise. Plasma atrial natriuretic peptide (ANP) and cyclic AMP (c-AMP) were measured at rest and at peak exercise test. ANP plasma levels at rest were significantly higher in VVI pacing compared to 150 AVD (P less than 0.03). On exercise, ANP release was statistically increased only in DDD with 150 ms AVD, while in VVI it remained in high levels at exercise but no significant change was found (p:ns). c-AMP during rest was unchanged in any pacing mode or AVD, but on exercise DDD pacing with short AVD (100 ms) released lower c-AMP plasma levels, than at rest (p:ns). DDD pacing with long AVD (150 ms) during exercise produced statistically higher c-AMP plasma levels (P less than 0.05) than at rest. Also in VVI pacing the c-AMP plasma levels were statistically higher than at rest (P less than 0.02). Adrenergic activity seems to be lower during exercise in DDD pacing with shorter AVD (100 ms) than in DDD with 150 ms AVD or VVI pacing. No difference was found in c-AMP plasma levels at rest. ANP release was also found to be lower at exercise in DDD pacing with short AVD (100 ms) than in DDD with 150 ms AVD. ANP plasma levels at rest were statistically higher in VVI pacing.
No takes yet. Share an insight, caveat, or question.
Theodorakis et al. (1990) studied complete heart block (n=9). VVI and DDD pacing with different AV delays vs. Different pacing modes (VVI vs DDD 100 ms vs DDD 150 ms) was evaluated on Plasma atrial natriuretic peptide (ANP) and cyclic AMP (c-AMP) levels at rest and peak exercise (p=<0.03).
Synapse has enriched 10 related papers. Consider them for comparative context: