Key result
Artificial valvular replacement for diseased aortic valves was associated with an overall operative mortality of 16%, with most deaths attributed to preventable factors.
Observational (n=90)
Analysis of 90 patients undergoing aortic valve replacement identified an operative mortality of 16%, with most contributing factors deemed preventable.
Answers are grounded in this paper and cite their sources.
May inform strategies to reduce preventable mortality; leaves open applicability to contemporary aortic valve replacement.
An analysis of the surgical management in relation to factors contributing to morbidity, mortality, and results in 90 patients having artificial valvular replacement for diseased aortic valves is presented. Twenty-four factors occurred in 15 patients which were responsible either alone or in combination for the deaths. These factors fell into five main groups related to the patient, the heart, the myocardial protection, the general body protection, and the valve. Most of these factors contributing to death are preventable. Therefore, the over-all operative mortality of 16 per cent should be materially reduced in the future.
No takes yet. Share an insight, caveat, or question.
Kay et al. (1962) conducted an observational in Diseased aortic valves (n=90). Artificial valvular replacement was evaluated on Operative mortality. Artificial valvular replacement for diseased aortic valves was associated with an overall operative mortality of 16%, with most deaths attributed to preventable factors.