Key result
Computational modeling demonstrates that the relatively high conductivity of blood causes stronger virtual electrode depolarizations in endocardial trabeculae grooves than in protrusions.
Computational modeling reveals that physiological conductivities and anatomical geometries, such as endocardial grooves and blood vessels, significantly influence virtual electrode formation during defibrillation.
Suggests blood conductivity shapes virtual electrodes in trabeculated ventricles; leaves open effects on clinical defibrillation thresholds.
BACKGROUND: Virtual electrodes from structural/conductivity heterogeneities are known to elicit wavefront propagation, upon field-stimulation, and are thought to be important for defibrillation. In this work we investigate how the constitutive and geometrical parameters associated with such anatomical heterogeneities, represented by endo/epicardial surfaces and intramural surfaces in the form of blood-vessels, affect the virtual electrode patterns produced. METHODS AND RESULTS: The steady-state bidomain model is used to obtain, using analytical and numerical methods, the virtual electrode patterns created around idealized endocardial trabeculations and blood-vessels. The virtual electrode pattern around blood-vessels is shown to be composed of two dominant effects; current traversing the vessel surface and conductivity heterogeneity from the fibre-architecture. The relative magnitudes of these two effects explain the swapping of the virtual electrode polarity observed, as a function of the vessel radius, and aid in the understanding of the virtual electrode patterns predicted by numerical bidomain modelling. The relatively high conductivity of blood, compared to myocardium, is shown to cause stronger depolarizations in the endocardial trabeculae grooves than the protrusions. CONCLUSIONS: The results provide additional quantitative understanding of the virtual electrodes produced by small-scale ventricular anatomy, and highlight the importance of faithfully representing the physiology and the physics in the context of computational modelling of field stimulation.
No takes yet. Share an insight, caveat, or question.
Connolly et al. (2017) studied Ventricular fibrillation / Defibrillation. Electric field stimulation was evaluated on Virtual electrode patterns and transmembrane potential. Computational modeling demonstrates that the relatively high conductivity of blood causes stronger virtual electrode depolarizations in endocardial trabeculae grooves than in protrusions.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: