Key result
Transapical off-pump NeoChord implantation achieves early procedural success without complications in 2 severe MR patients.
Why the study?
Does transapical off-pump artificial chordae implantation using the NeoChord system provide a feasible and safe treatment in patients with severe mitral regurgitation due to posterior leaflet prolapse?
Case Report (n=2)
Does transapical off-pump artificial chordae implantation using the NeoChord system provide a feasible and safe treatment in patients with severe mitral regurgitation due to posterior leaflet prolapse?
Transapical off-pump artificial chordae implantation using the NeoChord system is a feasible and safe technique for treating severe mitral regurgitation due to posterior leaflet prolapse.
Answers are grounded in this paper and cite their sources.
May enable off-pump mitral repair in selected patients; leaves open durability, safety, and comparative efficacy.
BACKGROUND: Artificial chord implantation to repair a flail or prolapsing mitral valve leaflet requires open heart surgery and cardiopulmonary bypass. AIM: Transapical off-pump artificial chordae implantation is a new surgical technique proposed to treat degenerative mitral valve regurgitation. The procedure is performed using the NeoChord DS1000 system (NeoChord, Inc., St. Louis Park, MN, USA), which facilitates both implantation and lenght adjustment of the artificial chordae under two (2D)- and three (3D)-dimensional transoesophageal echocardiographic (TEE) guidance on a beating heart. METHODS: Two male patients aged 60 and 55 years with severe mitral regurgitation due to posterior leaflet prolapse underwent transapical off-pump artificial chordae implantation on September 3, 2015. The procedure was performed by left minithoracotomy under general anaesthesia in a cardiac surgical theatre, using 2D and 3D TEE guidance. RESULTS: Early procedural success as confirmed by 3D TEE was achieved in both patients, with implantation of 6 artificial chordae in the first patient and 3 artificial chordae in the second patient. Both procedures were uneventful, and no postoperative complications were noted. The patients were discharged home on the 8th and 6th postoperative day, respectively. CONCLUSIONS: The NeoChord DS1000 system allows both implantation and lenght adjustment of artificial chordae under 2D and 3D TEE guidance on a beating heart. Our initial experience in 2 patients with posterior mitral leaflet prolapse indicates that the procedure is feasible and safe.
No takes yet. Share an insight, caveat, or question.
Wróbel et al. (2016) conducted a case report in Severe mitral regurgitation due to posterior leaflet prolapse (n=2). Transapical off-pump artificial chordae implantation (NeoChord DS1000 system) was evaluated on Early procedural success. Transapical off-pump artificial chordae implantation using the NeoChord DS1000 system achieved early procedural success in 2 patients with severe mitral regurgitation, with no complications.
Synapse has enriched 10 related papers. Consider them for comparative context: