Key result
Preoperative MDCT successfully maps cardiac veins in ~99% of patients with ischemic or dilated cardiomyopathy.
Why the study?
Can preoperative MDCT effectively map cardiac veins to assess availability for LV lead placement in CRT patients?
Observational (n=99)
Can preoperative MDCT effectively map cardiac veins to assess availability for LV lead placement in CRT patients?
Preoperative MDCT can successfully map cardiac veins to identify suitable targets for LV lead placement in CRT, regardless of cardiomyopathy etiology.
May support preoperative MDCT for vein mapping in CRT planning; leaves open impact on lead placement success.
BackgroundSuccessful cardiac resynchronization therapy (CRT) requires appropriate left ventricular (LV) lead placement on a suitable segment of the free LV wall. Current guidelines suggest targeted lead placement, but the individual anatomy of the cardiac veins is often a limiting factor. PurposeTo map cardiac veins with multidetector computed tomography (MDCT) and plot the veins in cardiac segments to facilitate successful CRT implantation. Material and MethodsNinety-nine patients were included (mean age = 68 ± 9 years; 26% women; 46% ischemic cardiomyopathy). Contrast-enhanced, ECG-gated, dose-modulated MDCT was used to depict the coronary veins. CT data were reformatted into short-axis view. Veins with diameter ≥1.5 mm and traversing the free LV wall were manually transferred into a 17-segment bulls-eye plot model. ResultsIn 98 patients, a CT scan with acceptable image quality was obtained. Median radiation dose as dose-length protocol was 231 mGy/cm (interquartile range = 276 mGy/cm). Mean contrast dose, expressed as total iodine load, was 38 ± 8 g. A median of three suitable veins (range = 1–7) covered a mean of 4.4 ± 1.5 relevant LV segments. There was no difference between patients with dilated or ischemic cardiomyopathy in number of veins (2.5 vs. 2.7, P = 0.45) or in number of cardiac segments traversed by suitable veins (4.4 vs. 4.5, P = 0.74). ConclusionIn CRT patients, MDCT can be used for preoperative mapping of the cardiac veins to assess availability of suitable veins in potential target segments for pacemaker-lead placement. Using the 17-segment plot of the left ventricle may improve the clinical usefulness of the data.
No takes yet. Share an insight, caveat, or question.
Markstad et al. (2018) conducted an observational in Cardiac resynchronization therapy (CRT) (n=99). Preoperative multidetector computed tomography (MDCT) was evaluated on Number of suitable veins covering relevant LV segments.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: