Key result
Suction-based right atrial positioning achieves 100% feasibility during off-pump surgical AF ablation.
Why the study?
Does right atrial positioning using a suction-based cardiac positioner provide safe and feasible exposure of right pulmonary veins during off-pump atrial fibrillation ablation?
Observational (n=34)
Does right atrial positioning using a suction-based cardiac positioner provide safe and feasible exposure of right pulmonary veins during off-pump atrial fibrillation ablation?
Right atrial exposure using a suction-based cardiac positioner is a safe and feasible technique for visualizing right pulmonary veins during off-pump surgical ablation for atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May facilitate right PV exposure in off-pump AF ablation; hypothesis-generating and requires prospective validation.
OBJECTIVES: Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. METHODS: Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. RESULTS: In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. CONCLUSIONS: This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins.
No takes yet. Share an insight, caveat, or question.
Suwalski et al. (2017) conducted an observational in Atrial fibrillation (n=34). Right atrial positioning using a suction-based cardiac positioner was evaluated on Safety and feasibility. Right atrial positioning using a suction-based cardiac positioner achieved feasibility endpoints in 100% of patients undergoing off-pump surgical ablation for atrial fibrillation.
Synapse has enriched 10 related papers. Consider them for comparative context: