Key result
Carpentier-Edwards valve matches Mosaic 10-year survival but reduces paravalvular leaks and reoperations.
Why the study?
Does the Carpentier-Edwards supra-annular valve improve clinical outcomes compared to the Medtronic Mosaic prosthesis in patients undergoing bioprosthetic aortic valve replacement?
RCT (n=394)
Does the Carpentier-Edwards supra-annular valve improve clinical outcomes compared to the Medtronic Mosaic prosthesis in patients undergoing bioprosthetic aortic valve replacement?
Absolute Event Rate: 59.7% vs 54.2%
p-value: p=0.27
The CE-SAV aortic bioprosthesis showed superior 10-year freedom from paravalvular leak and reoperation compared to the Mosaic bioprosthesis, though overall survival was similar.
Mosaic valves linked to more paravalvular leaks and reoperations than CE-SAV at 10 years; challenges assumed equivalence of these porcine aortic bioprostheses.
OBJECTIVES: We performed a prospective randomized study comparing the clinical performance of the Carpentier-Edwards supra-annular valve (CE-SAV) (Edwards Lifesciences, Irvine, CA, USA) and the newer Mosaic (Medtronic Corporation, Minneapolis, MN, USA) porcine bioprostheses in the aortic position over a 10-year period. METHODS: Between January 2001 and March 2005, 394 patients undergoing bioprosthetic aortic valve replacement were randomized to receive either the CE-SAV (n = 191) or the Mosaic (n = 203) prosthesis. The preoperative demographics, EuroSCORE and intraoperative characteristics concerning cardiopulmonary bypass of the 2 groups were comparable. All patients were followed annually for 10 years. RESULTS: There were 77 (40.3%) deaths in the CE-SAV group and 93 (45.8%) deaths in the Mosaic group. The 10-year survival rate in the 2 groups was 59.7% and 54.2%, respectively (P = 0.27). There were no statistically significant differences between the 2 groups in terms of structural valve deterioration (P = 0.08), endocarditis (P = 0.95), thromboembolism (P = 0.06) and major bleeds (P = 0.09). However, the incidence of paravalvular leaks and valve-related reoperations were higher in the Mosaic group, with 5 leaks and 6 reoperations when compared to none in the CE-SAV group, (P = 0.02) and (P = 0.01) respectively. CONCLUSIONS: At 10 years after implantation, freedom from reoperation was greater in the CE-SAV group with no incidences of paravalvular leaks. There were no other statistically significant differences between CE-SAV and Mosaic aortic prostheses. Clinical trial registration: clinicaltrial.gov ID 1301 (NCT03346044).
No takes yet. Share an insight, caveat, or question.
Zibdeh et al. (2017) conducted an RCT in Bioprosthetic aortic valve replacement (n=394). Carpentier-Edwards supra-annular valve (CE-SAV) vs. Mosaic porcine bioprosthesis was evaluated on 10-year survival rate (p=0.27). The Carpentier-Edwards supra-annular valve showed similar 10-year survival to the Mosaic prosthesis (59.7% vs 54.2%, P=0.27), but had significantly fewer paravalvular leaks and reoperations.