Key result
Rapid atrial pacing to the Wenckebach point strongly correlates with AV node FRP and ERP.
Why the study?
Does rapid atrial pacing correlate with extrastimulus refractory period measurements for assessing atrioventricular conduction in patients undergoing cardiac catheterization?
Observational (n=41)
Does rapid atrial pacing correlate with extrastimulus refractory period measurements for assessing atrioventricular conduction in patients undergoing cardiac catheterization?
Effect estimate: r=0.89
p-value: p=<0.01
No takes yet. Share an insight, caveat, or question.
Rapid atrial pacing is a reliable test of A-V conduction that closely correlates with refractory period measurements obtained via the extrastimulus technique.
Bissett et al. (1975) conducted an observational in Patients undergoing diagnostic cardiac catheterization (n=41). Rapid atrial pacing vs. Refractory period measurements utilizing the extrastimulus technique was evaluated on Correlation between Wenckebach point (WP) and functional refractory period (FRP) of the A-V node (r=0.89, p=<0.01). Rapid atrial pacing to the Wenckebach point correlated significantly with the functional refractory period of the A-V node (r=0.89, P<0.01) and the effective refractory period (r=0.81).