Key result
Mitral flow propagation velocity <50 cm/s reliably identifies diastolic dysfunction in CABG patients.
Why the study?
Does mitral flow propagation velocity (Vp) accurately identify abnormal diastolic function compared to standard Doppler techniques in patients undergoing coronary artery bypass graft surgery?
Observational (n=63)
Does mitral flow propagation velocity (Vp) accurately identify abnormal diastolic function compared to standard Doppler techniques in patients undergoing coronary artery bypass graft surgery?
Mitral flow propagation velocity (Vp <50 cm/s) is a reliable, load-independent echocardiographic marker for identifying diastolic dysfunction during CABG surgery, particularly useful when standard Doppler techniques are uninterpretable.
May aid diastolic assessment in CABG when Doppler is limited; hypothesis-generating and requires prospective validation.
Flow propagation velocity (Vp) is a new method of assessing left ventricular (LV) diastolic (D) function that seems to be insensitive to heart rate and preload changes. We hypothesized that Vp <50 cm/s identifies patients with D dysfunction and that Vp provides an assessment of D function when standard Doppler techniques are uninterpretable. We conducted a prospective Doppler echocardiographic assessment of D function in 63 patients undergoing coronary artery bypass graft surgery. Doppler derivatives of mitral inflow and pulmonary vein flow profiles as well as isovolumic relaxation time were compared with Vp before and after cardiopulmonary bypass. A Valsalva maneuver was used to decrease preload. All patients with D dysfunction had Vp <50 cm/s. A Valsalva maneuver did not affect Vp. Vp remained a reliable measure of LV D function when mitral flow profiles could not be determined because of changes in heart rate and rhythm. LV filling patterns did not change significantly after cardiopulmonary bypass. We conclude that Vp is a simple measure of D function during coronary artery bypass graft surgery that correlates with standard, load-dependent Doppler echocardiographic techniques to identify D dysfunction. Vp <50 cm/s identifies abnormal D function in this patient population.
No takes yet. Share an insight, caveat, or question.
Djaiani et al. (2002) conducted an observational in Coronary artery disease requiring bypass graft surgery (n=63). Flow propagation velocity (Vp) vs. Standard Doppler techniques was evaluated on Identification of diastolic dysfunction. Flow propagation velocity <50 cm/s reliably identified abnormal diastolic function in all affected patients undergoing coronary artery bypass graft surgery.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: