Key result
Flow propagation velocity (Vp) <50 cm/s reliably identified abnormal diastolic function during coronary artery bypass graft surgery, even when standard Doppler techniques were uninterpretable.
Why the study?
Does mitral flow propagation velocity (Vp) identify abnormal diastolic function in patients undergoing coronary artery bypass graft surgery?
Observational (n=63)
Does mitral flow propagation velocity (Vp) identify abnormal diastolic function in patients undergoing coronary artery bypass graft surgery?
Mitral flow propagation velocity (Vp <50 cm/s) is a simple, load-independent echocardiographic measure that reliably identifies diastolic dysfunction during CABG surgery, even when standard Doppler techniques are uninterpretable.
Answers are grounded in this paper and cite their sources.
May support Vp for intraoperative diastolic assessment in CABG when Doppler fails; leaves open prospective validation before routine use.
UNLABELLED: Flow propagation velocity (Vp) is a new method of assessing left ventricular (LV) diastolic (D) function that seems to be insensitive to heart rate and preload changes. We hypothesized that Vp <50 cm/s identifies patients with D dysfunction and that Vp provides an assessment of D function when standard Doppler techniques are uninterpretable. We conducted a prospective Doppler echocardiographic assessment of D function in 63 patients undergoing coronary artery bypass graft surgery. Doppler derivatives of mitral inflow and pulmonary vein flow profiles as well as isovolumic relaxation time were compared with Vp before and after cardiopulmonary bypass. A Valsalva maneuver was used to decrease preload. All patients with D dysfunction had Vp <50 cm/s. A Valsalva maneuver did not affect Vp. Vp remained a reliable measure of LV D function when mitral flow profiles could not be determined because of changes in heart rate and rhythm. LV filling patterns did not change significantly after cardiopulmonary bypass. We conclude that Vp is a simple measure of D function during coronary artery bypass graft surgery that correlates with standard, load-dependent Doppler echocardiographic techniques to identify D dysfunction. Vp <50 cm/s identifies abnormal D function in this patient population. IMPLICATIONS: Mitral propagation velocity (Vp) is a simple, reproducible measure of diastolic function during coronary artery bypass graft surgery that correlates with standard Doppler echocardiographic techniques to identify dysfunction in the setting of a rapid heart rate or variable preload. Vp <50 cm/s identifies abnormal diastolic function in this patient population.
No takes yet. Share an insight, caveat, or question.
Djaiani et al. (2002) conducted an observational in Coronary artery disease requiring bypass graft surgery (n=63). Flow propagation velocity (Vp) vs. Standard Doppler echocardiographic techniques was evaluated on Identification of left ventricular diastolic dysfunction. Flow propagation velocity (Vp) <50 cm/s reliably identified abnormal diastolic function during coronary artery bypass graft surgery, even when standard Doppler techniques were uninterpretable.
Synapse has enriched 10 related papers. Consider them for comparative context: