Key result
Intermittent pneumatic compression boots fail to alter central hemodynamics in heart failure.
Why the study?
Does the use of intermittent pneumatic compression boots alter central hemodynamic parameters in patients with congestive heart failure?
Does the use of intermittent pneumatic compression boots alter central hemodynamic parameters in patients with congestive heart failure?
Answers are grounded in this paper and cite their sources.
Intermittent pneumatic compression boots do not significantly alter central hemodynamics in CHF patients, suggesting they may be safely used for venous thromboembolic risk reduction despite theoretical contraindications.
The use of intermittent pneumatic compression boots to reduce the risk of deep venous thrombosis is contraindicated in patients with congestive heart failure (CHF) due to a theoretical increase in venous return to the heart and exacerbation of heart failure. This study evaluates intermittent pneumatic compression effects on pulmonary artery catheter parameters in CHF patients. We conducted a prospective within-patient study of CHF patients monitored by pulmonary artery catheterization. Hemodynamic variables were assessed with and without the use of intermittent pneumatic compression boots. A sample size of 18 patients was calculated a priori to obtain an 80 per cent power to detect a mean difference of 10 per cent. Twenty patients were studied; no patient suffered hemodynamic instability during the application of pneumatic compression; no statistically significant change in any hemodynamic parameters was noted. A trend toward decreasing mean arterial blood pressure (P = 0.057), pulmonary artery wedge pressure (P = 0.065), and systemic vascular resistance (P = 0.08) was observed. None were clinically significant. The application of intermittent pneumatic compression to the feet of patients in CHF does not significantly alter central hemodynamic parameters in CHF patients. This study suggests that intermittent pneumatic compression may be used in CHF patients for venous thromboembolic risk reduction.
No takes yet. Share an insight, caveat, or question.
Ringley et al. (2002) studied congestive heart failure (n=20). intermittent pneumatic compression boots vs. without intermittent pneumatic compression boots was evaluated on central hemodynamic parameters. Intermittent pneumatic compression boots did not significantly alter central hemodynamic parameters in patients with congestive heart failure.
Synapse has enriched 10 related papers. Consider them for comparative context: