Key result
S-ICD effectively prevents sudden cardiac death as an alternative to transvenous ICDs, avoiding intravascular lead complications.
Answers are grounded in this paper and cite their sources.
The S-ICD provides effective sudden cardiac death prevention while avoiding the intravascular lead complications of transvenous systems, though it currently lacks pacing capabilities.
Towards Optimizing the Risk-Benefit Profile of ICD Therapy The concept of preventing sudden cardiac death (SCD) by providing patients with an implantable cardioverter defibrillator (ICD) was revolutionary when it was first introduced into clinical practice in the early 1980s. While bulky, inconvenient, difficult to implant, and unable to be programmed, these early devices were continuously refined and eventually replaced by the current standard of transvenous ICDs by the late 1980s/early 1990s. Ongoing improvements in algorithms, material and knowledge gradually improved the devices’ efficacy and safety further, advancing the ICD to become standard therapy for SCD prevention for at risk patients. However, even to date, complications associated with these systems are not negligible with the electrode in the right ventricle constituting the weakest link in the system. Indeed, leads are prone to various stressors over time, including abrasion between the clavicle and the first rib as well as during its intravascular and extravascular course. Closely related is the problem of infection: due to its intravascular course, the ICD electrode is continuously exposed to potential pathogens; in addition, the device itself may become infected, a risk which exponentially increases with every device exchange over time. Once infected, whether it is primarily the lead or the device, explantation of the entire system including extraction of the lead is usually inevitable. Lead extraction in turn, comes at its own risk of severe to life-threatening complications depending on the dwell time of the electrode(s). Implantation of the S-ICD. Left panel: The electrode is tunnelled from the pocket (lower left side of the image) to the supraxiphoid area. Afterwards, it is tunnelled cranially along the sternal border with the help of a peel-away sheath (Center panel), followed by fixation of the lead and implantation of the device (Right panel). Implanted S-ICD (X-ray). The whole system, including the electrode, is hence located outside the vascular system, and in fact outside the thoracic cage. As a result, it is by far less prone to infection as has recently been demonstrated in a sizable propensity score-matched cohort study comparing the S-ICD with conventional transvenous systems. Moreover, the lead is less prone to fracture due to its fundamentally different more robust design, lacking both a lumen as well as the flexibility usually required for transvenous leads. At the same time, the system is highly effective in doing what it is supposed to—prevent SCD. Recently presented 3-years results from the large EFFORTLESS registry demonstrated a VT/VF conversion rate of 97.4%, which is similar to that of transvenous systems. At the same time, the S-ICD system is undergoing substantial improvements to prevent inappropriate shocks. With the latest technology of a high-pass filter designed to further reduce the risk of T-Wave oversensing (one of the most frequent causes of inappropriate therapy in S-ICDs), the rate of inappropriate therapies is further reduced and is now estimated in the range of 3.8% in the 1st year after implantation. Hence, well in the range of that observed with transvenous ICDs. With all the advantages of the S-ICD, some limitations remain. Due to the lack of an electrode, the device is unable to deliver bradycardia pacing, antitachycardia pacing for monomorphic VT, or cardiac resynchronization therapy. However, in the afore mentioned registry the overall necessity of exchanging the system in order to be able to deliver such therapies was low (around 1%). Moreover, the development to combine the S-ICD with another highly innovative device therapy—leadless pacing—is advancing at full speed. Indeed, first animal experience have indicated the feasibility to perform master-slave communication between the S-ICD and a leadless pacing capsule, hence enabling both bradycardia pacing as well as anti-tachycardia pacing if necessary. A dedicated randomized trial comparing the S-ICD with transvenous ICDs is ongoing. While this and other ongoing studies will demonstrate the system’s efficacy and safety over a time span of 2–3 years, the benefit of the S-ICD is likely to increase over time compared to transvenous systems, once the typical time frame of lead failures is encountered. While large-scale studies have been conducted, which proved the principle of ICDs to be effective in a series of primary and secondary prevention settings, the benefit of any system always needs to be counterbalanced by the potential morbidity and mortality that may come with it over time. In fact, nobody has a zero percent risk of sudden cardiac death; on the contrary, the largest absolute number of SCDs is occurring in the general population without discernible risks or predictors—the primary challenge of the Myerburg Paradox. As a result, everybody would be a potential candidate for implantation with the ‘ideal ICD’ that comes with zero morbidity (and ideally, zero cost). While we are still a long stretch away from this scenario, having a defibrillator system available with less morbidity—such as the S-ICD—may tip the risk-benefit ratio of ICD therapy towards a net benefit for patients in whom conversely, the risks are thought to outweigh the benefits with conventional transvenous systems. It may hence make SCD prevention available to lower risk individuals such as patients with only mildly (instead of severely) reduced LV function, or heart failure with preserved (instead of reduced) LV function and others, who are currently not eligible for this life-saving therapy. Large-scale randomized controlled trials are required (and are in part already planned/ongoing) to prove the efficacy and safety of the S-ICD in these indications to enable an even larger cohort of patients to be protected from SCD. Conflict of interest: J.S has received consultant and/or speaker fees from Amgen, Astra-Zeneca, Atricure, Bayer, Biosense Webster, Biotronik, Boehringer-Ingelheim, Boston Scientific, Bristol-Myers Squibb, Cook Medical, Daiichi Sankyo, Medtronic, Novartis, Pfizer, Sanofi-Aventis, Sorin, St. Jude Medical and Zoll. J.S is Co-director of CorXL. J.S has received grant support through his institution from Bayer Healthcare, Biosense Webster, Biotronik, Boston Scientific, Daiichi Sankyo, Medtronic, und St. Jude Medical.
No takes yet. Share an insight, caveat, or question.
Jan Steffel (2017) conducted a review in Sudden cardiac death. Subcutaneous Implantable Cardioverter Defibrillator (S-ICD) vs. Transvenous ICDs was evaluated. The subcutaneous implantable cardioverter defibrillator is an effective alternative to transvenous systems for preventing sudden cardiac death, avoiding intravascular lead complications.
Synapse has enriched 10 related papers. Consider them for comparative context: