Key result
Continuous ICE and dual transcatheter cerebral protection enable successful extraction of a misplaced LV lead.
Why the study?
Misplacement of pacing leads in the left ventricle is rare and associated with embolic complications.
Demonstrates a technique for extracting misplaced left ventricular pacing leads using intracardiac echocardiography and dual cerebral embolic protection devices to prevent embolic complications.
Answers are grounded in this paper and cite their sources.
May enable protected extraction of misplaced LV leads; leaves open prospective safety validation before adoption.
Misplacement of pacing leads in the left ventricle (LV) is rare and is associated with embolic complications. We present a case of extraction of a left ventricular lead using continuous intracardiac echocardiography visualization and complete encephalic circulation protection with 2 transcatheter cerebral embolic protection devices.
No takes yet. Share an insight, caveat, or question.
Motta et al. (2024) studied this question. Extraction of a misplaced left ventricular pacing lead was achieved using continuous intracardiac echocardiography and complete cerebral protection with two transcatheter devices.
Synapse has enriched 10 related papers. Consider them for comparative context: