Key result
Angiopeptin-eluting stents appear safe and feasible with 0% major cardiovascular events at one year.
Why the study?
Does angiopeptin-eluting stent implantation prevent restenosis and neointimal hyperplasia in patients with native de novo coronary lesions?
Does angiopeptin-eluting stent implantation prevent restenosis and neointimal hyperplasia in patients with native de novo coronary lesions?
The first human experience with angiopeptin-eluting stents demonstrates feasibility, safety, and modest neointimal hyperplasia in native de novo coronary lesions.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for angiopeptin-eluting stents; should not yet change practice pending larger trials.
Angiopeptin has been shown to reduce in-stent restenosis in various animal models. Meanwhile, BiodivYsio DD phosphorylcholine (PC)-coated stent provides a platform for local delivery of antiproliferative agents to the coronary artery. We studied the feasibility, safety, and impact on tissue growth of angiopeptin-eluting BiodivYsio DD PC-coated stents in human native de novo coronary lesions. We enrolled 14 patients (16 lesions) who underwent intravascular ultrasound (IVUS)-guided angiopeptin-eluting stent implantation in native coronary arteries between 3.0 and 4.0 mm in diameter with lesion length ≤ 18 mm. We successfully implanted 13 stents loaded with 22 μg of angiopeptin and three stents with 126 μg of angiopeptin. No major adverse cardiac events or target vessel failure occurred at 1-year clinical follow-up. All patients underwent 6-month angiographic and volumetric IVUS follow-up. In-stent late loss was 0.46 ± 0.32 mm in the low-dose group and 0.26 ± 0.14 mm in the high-dose group. Binary restenosis rate was 0%. Follow-up percentage neointimal hyperplasia by IVUS was 18.4% ± 22.5% for the low-dose group and 10.2% ± 5.8% for the high-dose group, respectively. There were no edge effect and late stent malapposition. Angiopeptin-eluting BiodivYsio DD PC stent appears feasible and safe in treating native de novo coronary lesions with modest degree of neointimal hyperplasia.
No takes yet. Share an insight, caveat, or question.
Kwok et al. (2005) studied Native de novo coronary lesions (n=14). Angiopeptin-eluting BiodivYsio DD PC-coated stent was evaluated on Major adverse cardiac events or target vessel failure. Angiopeptin-eluting stent implantation in native de novo coronary lesions was feasible and safe, with 0% major adverse cardiac events and 0% binary restenosis at 1-year follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: