Key result
Lower brachial artery FMD strongly correlates with a higher coronary stenosis index.
Why the study?
The relationship between flow-mediated dilation of the brachial artery and the extent and severity of coronary artery disease was examined to understand vascular impairment in CAD.
Does brachial artery flow-mediated dilation correlate with the angiographic severity of coronary artery disease?
Cross-Sectional (n=121)
Does brachial artery flow-mediated dilation correlate with the angiographic severity of coronary artery disease?
Answers are grounded in this paper and cite their sources.
Brachial artery flow-mediated dilation is inversely correlated with the angiographic severity of coronary artery disease, suggesting its utility as a non-invasive marker of coronary atherosclerosis.
We examined the relationship between flow-mediated dilation (FMD) of the brachial artery and the extent and severity of coronary artery disease (CAD). Using high-resolution ultrasonography, we measured FMD and nitroglycerin-induced brachial artery dilation. We studied 121 patients (77 men, 44 women; mean age 64+/-11 years, range 25-79 years) who underwent coronary arteriography. The extent and severity of CAD were assessed by the coronary stenosis index (CSI). The adjusted FMD correlated inversely with CSI (rs=-0.63, p<0.0001). Multivariate analysis demonstrated that the adjusted FMD was an independent predictor of CSI. The adjusted FMD was 10.2+/-4.8% in patients without CAD (n=32), 7.7+/-6.0% in patients with single-vessel disease (n=31), 5.2+/-5.5% in patients with double-vessel disease (n=29), and 2.0+/-3.9% in patients with triple-vessel disease (n=29). The adjusted FMD was significantly lower in the double- (p<0.01) and triple-vessel (p<0.0001) disease groups than in patients without CAD. The adjusted FMD was significantly lower in the triple-vessel disease group than in the single-vessel disease group (p<0.001). Based on our results, as coronary atherosclerosis becomes more severe, the adjusted brachial artery FMD becomes more severely impaired.
No takes yet. Share an insight, caveat, or question.
Kaku et al. (1998) conducted a cross-sectional in Coronary artery disease (n=121). Flow-mediated dilation (FMD) of the brachial artery vs. Patients without CAD was evaluated on Correlation between adjusted FMD and coronary stenosis index (CSI) (rs=-0.63, p=<0.0001). Adjusted brachial artery flow-mediated dilation correlated inversely with the coronary stenosis index, indicating more severe impairment with worsening coronary atherosclerosis.
Synapse has enriched 10 related papers. Consider them for comparative context: