Key result
Age-adjusted D-dimer increases specificity for ruling out acute aortic syndrome by ~6% vs conventional cutoffs.
Why the study?
D-dimer increases with age, and it was uncertain whether an age-adjusted D-dimer cutoff could improve diagnostic accuracy in ruling out acute aortic syndrome.
Does an age-adjusted D-dimer cutoff improve diagnostic accuracy for ruling out acute aortic syndrome in adult emergency room patients compared to a conventional cutoff?
Observational (n=204)
Does an age-adjusted D-dimer cutoff improve diagnostic accuracy for ruling out acute aortic syndrome in adult emergency room patients compared to a conventional cutoff?
Using an age-adjusted D-dimer cutoff in patients over 50 years old improves specificity and positive predictive value for ruling out acute aortic syndrome without compromising sensitivity.
Answers are grounded in this paper and cite their sources.
Age-adjusted D-dimer may aid AAS rule-out in older ED patients; leaves open prospective validation before practice change.
Background. Recently, D-dimer has been suggested as a biomarker to rule out acute aortic syndrome (AAS). Since it increases with age, this study was conducted to reveal whether an age-adjusted D-dimer can increase diagnostic accuracy in ruling out AAS. Method. A retrospective observational study design was used. Consecutive adult patients who visited an emergency room between January 2015 and September 2020 and who underwent a D-dimer test and computed tomography angiography for suspected AAS were enrolled. We calculated the diagnostic accuracy of both the conventional (0.5 μg/ml) and age-adjusted (age × 0.01 in patients >50 years) D-dimer cut-offs. Result. D-dimer was higher in the AAS group (n = 82) than in the non-AAS group (n = 122) (10.85 (3.61–33.12) vs. 0.40 (0.23–1.07), OR: 1.139 (CI: 1.085 – 1.195), p < 0.001 ). The D-dimer plasma level had an area under the ROC curve of 0.915 (CI: 0.873–0.956) with AAS. At the age-adjusted cutoff point compared to a 0.5 μg/ml cutoff, the sensitivity of 97.6% and the NLR of 0.04 did not change, but the specificity increased by 5.7% to 65.6%, the PPV increased by 3.6% to 65.6%, and the NPV slightly increased by 0.2% to 97.6%. Conclusion. Compared with a conventional method, the age-adjusted D-dimer cutoff may have higher specificity and PPV while maintaining high sensitivity for ruling out AAS.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2022) conducted an observational in Acute aortic syndrome (n=204). Age-adjusted D-dimer cutoff vs. Conventional D-dimer cutoff (0.5 μg/ml) was evaluated on Acute aortic syndrome (OR 1.139, 95% CI 1.085-1.195, p=<0.001). An age-adjusted D-dimer cutoff increased specificity for ruling out acute aortic syndrome to 65.6% while maintaining 97.6% sensitivity compared to a conventional /ml cutoff.