Key result
MitraClip XTR successfully reduces severe TR and prevents HF hospitalizations for over 6 months.
Why the study?
Severe tricuspid valve regurgitation is associated with high cardiovascular mortality and safe, feasible interventional treatments are clinically relevant.
Case Report (n=1)
The new MitraClip XTR System with wider clip arms is feasible and effective for percutaneous edge-to-edge repair of complex tricuspid regurgitation with a large coaptation gap.
Answers are grounded in this paper and cite their sources.
Supports feasibility of MitraClip XTR in complex TR; hypothesis-generating and requires prospective validation before practice change.
BACKGROUND Severe tricuspid valve regurgitation (TR) is associated with high cardiovascular mortality. Safe and feasible interventional approaches to treat severe TR are of clinical relevance. The MitraClip is a device that has been approved by the US Food and Drug Administration (FDA) for the repair of mitral valve lesions. Percutaneous femoral venous access with fluoroscopic and echocardiographic guidance is used to deliver a cobalt-chromium clip to secure the mitral valve leaflets. We report on an 85-year-old man with tricuspid valve regurgitation who underwent percutaneous edge-to-edge tricuspid valve leaflet plication with the new, advanced MitraClip XTR System. CASE REPORT An 85-year-old man with severe TR due to annulus dilation of the right ventricle and short septal leaflet presented repeatedly at our hospital with severe right heart failure symptoms. Transesophageal echocardiography revealed severe TR with a large coaptation gap size of 10.6 mm. Percutaneous edge-to-edge valve repair with the new-generation MitraClip System XTR with wider clip arms could overcome the large coaptation gap. We achieved a strong reduction of TR after deploying 2 MitraClips XTR. The patient recovered quickly and has not been admitted to hospital due to heart failure symptoms since the intervention for more than 6 months. CONCLUSIONS Previous studies have shown the safety and effectiveness of the MitraClip device and supported FDA approval for tricuspid valve repair. This report of a patient with complex tricuspid regurgitation demonstrated the feasible use of the new MitraClip XTR System, which improved edge-to-edge tricuspid valve repair due to its increased span and improved grip.
No takes yet. Share an insight, caveat, or question.
Mueller et al. (2020) conducted a case report in Severe tricuspid valve regurgitation (n=1). MitraClip XTR System was evaluated on Reduction of TR and heart failure symptoms. Percutaneous edge-to-edge tricuspid valve repair using the MitraClip XTR System successfully reduced severe tricuspid regurgitation and prevented heart failure hospitalizations for over 6 months.
Synapse has enriched 10 related papers. Consider them for comparative context: