Key result
AlbuSure detects urinary albumin with ~95% specificity compared to immunonephelometry.
Why the study?
The ability of AlbuSure to identify IDDM subjects at increased risk for diabetic nephropathy and its reproducibility had not been fully evaluated.
Does the AlbuSure qualitative test accurately detect elevated urinary albumin and identify IDDM subjects at risk for diabetic nephropathy?
Cohort (n=154)
Does the AlbuSure qualitative test accurately detect elevated urinary albumin and identify IDDM subjects at risk for diabetic nephropathy?
AlbuSure is a valid and reproducible qualitative test for detecting elevated urinary albumin, particularly using overnight urine samples, to identify IDDM patients at risk for diabetic nephropathy.
Answers are grounded in this paper and cite their sources.
AlbuSure may aid albuminuria screening in IDDM; leaves open outcome validation before routine adoption.
This study, which included 154 participants in a 10-yr follow-up study of diabetes complications, was conducted to evaluate AlbuSure (a qualitative test designed to detect urinary albumin concentrations greater than 0.03 g/L) for its ability to discriminate between albumin concentrations above and below the manufacturer's concentration threshold and to identify individuals at increased risk for developing diabetic nephropathy (i.e., those with albumin excretion rate [AER] greater than 0.0288 g/24 h). The reproducibility of AlbuSure results was also evaluated. The results of these evaluations were examined by three different types of urine collections (24 h, overnight, and timed postclinic) and overall. AlbuSure's validity was examined by comparing its results to immunonephelometrically measured concentrations and AER. When compared to albumin concentration, AlbuSure had an overall sensitivity of 81.8%, specificity of 94.8%, and positive predictive value of 90.6%. AlbuSure's sensitivity was lower (71.4%) when compared with AER; however, this was higher than the sensitivity achieved by dipsticks against AER (50.7%). On testing urine samples stored for 3 days at 4 degrees C, AlbuSure results were 100% reproducible after 1 day and had an overall reproducibility of 92% after 3 days. When urine was retested after 3 and 15 mo of storage at -70 degrees C, AlbuSure was greater than or equal to 90% reproducible, with some of the differing results attributable to corresponding changes in albumin concentration. The overnight sample appeared to be the sample of choice for testing with AlbuSure in that it showed excellent reproducibility and the highest sensitivity (compared to both albumin concentration and AER).
No takes yet. Share an insight, caveat, or question.
Coonrod et al. (1989) conducted a cohort in Insulin-Dependent Diabetes Mellitus (IDDM) (n=154). AlbuSure vs. Immunonephelometrically measured concentrations and albumin excretion rate (AER) was evaluated on Validity of AlbuSure compared to immunonephelometrically measured concentrations and AER. AlbuSure demonstrated an overall sensitivity of 81.8%, specificity of 94.8%, and positive predictive value of 90.6% when compared to immunonephelometrically measured albumin concentration.