Key result
Serum cTnI is specific but insensitive for pediatric acute cardiac rejection, identifying ~75% of grade 4 cases.
Why the study?
Early diagnosis of acute cardiac rejection in infant heart transplant recipients is crucial, but non-invasive methods have poor sensitivity compared to endomyocardial biopsies.
Is serum cardiac troponin I a reliable marker for diagnosing acute cardiac rejection in pediatric heart transplant recipients?
Observational (n=25)
Is serum cardiac troponin I a reliable marker for diagnosing acute cardiac rejection in pediatric heart transplant recipients?
Cardiac troponin I is a highly specific but poorly sensitive non-invasive marker for acute cardiac rejection in pediatric heart transplant recipients.
Acute rejection of the donor heart is a major cause of mortality in infant heart transplant recipients. The early diagnosis of acute cardiac rejection (ACR) is crucial. Non-invasive methods have shown poor sensitivity in detecting rejection when compared to endomyocardial biopsies (EMB). We assessed troponin I as a new marker to diagnose cardiac rejection. Serum cardiac troponin I (cTNI) levels were retrospectively analysed in 25 heart transplant patients (ages, 2 wk to 13 yr; mean age, 3 months) presenting 36 acute rejections. In early post-operative rejection and initially elevated cTNI levels, rejection was associated with a second increase of serum cTNI concentrations in 21% of the patients (p = 0.15). If cTNI levels were in normal range before ACR an elevation was monitored in 59% of the rejection periods (p < 0.05). In 25% of the cases (n = 9) cTNI levels remained in normal range during the rejection episode (<0.6 ng/mL), in 22% (n = 8) cTNI levels did not exceed pathological values from 0.6 to 1.5 ng/mL and in 53% (n = 19) the measured levels went beyond 1.5 ng/mL. Maximum concentrations of cTNI were measured mostly 12 d from the moment rejection was suspected (day 1) in patients (median day 3). However, cTNI levels were elevated for 2-43 d after ACR was diagnosed (median 10 d). Twenty per cent of the patients with grade 3 rejection (ISHLT) and 75% of the patients with grade 4 rejection had a corresponding elevated cTNI level (p = 0.013). No false-positive elevations of cTNI were documented. The present data demonstrate that cTNI is a not a sensitive but a specific marker of ACR in children.
No takes yet. Share an insight, caveat, or question.
Siaplaouras et al. (2003) conducted an observational in Acute cardiac rejection in heart transplant recipients (n=25). Serum cardiac troponin I (cTNI) was evaluated on Detection of acute cardiac rejection. Serum cardiac troponin I is a specific but not sensitive marker of acute cardiac rejection in children, with elevated levels in 75% of grade 4 rejections (P=0.013) and no false positives.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: