Key result
ASK-20 adherence questionnaire shows good internal consistency, test-retest reliability, and concurrent validity.
Why the study?
The psychometric properties of the ASK-20 questionnaire for assessing medication adherence barriers needed further examination in a medical center outpatient population.
Cross-Sectional (n=112)
Subset randomized to 2-week retest
No
Effect estimate: Cronbach's alpha 0.76; test-retest reliability 0.80
The ASK-20 questionnaire is a reliable and valid tool for assessing barriers to medication adherence in patients with chronic diseases.
ASK-20 shows adequate reliability and validity for adherence barriers in asthma, diabetes, and HF; leaves open longitudinal testing against objective measures before routine use.
OBJECTIVE: This study examined the psychometric properties of the ASK-20 questionnaire, which was developed to assess barriers to medication adherence. RESEARCH DESIGN AND METHODS: Patients with asthma, diabetes, and congestive heart failure were recruited from a university medical center. Participants in this convenience sample completed the ASK-20 questionnaire and other questionnaires. Approximately one-third of participants were randomized to a 2-week retest administration. Analyses examined the reliability and validity of the ASK-20. RESULTS: A total of 112 patients participated (75.9% female; mean age = 46.7 years). The ASK-20 had good internal consistency reliability (Cronbach's alpha = 0.76) and test-retest reliability (0.80). Concurrent validity was demonstrated through significant correlations with the Morisky Medication Adherence Scale (r = -0.61, p < 0.001), condition-specific measures, and the SF-12 Mental Component Summary score (r = -0.40, p < 0.001). The correlation of the ASK-20 with proportion of days covered by filled medication prescriptions in the past 6 months (based on pharmacy claims) was relatively weak (r = -0.13), but in the expected direction. The ASK-20 total score significantly discriminated among groups of patients who differed in self-reported indicators including the Morisky score; missing a medication dose in the past week; number of days medication was not taken as directed; and treatment satisfaction. CONCLUSION: The ASK-20 demonstrated adequate reliability and validity, and it may be a useful measure of barriers to treatment adherence across a spectrum of chronic diseases. Limitations related to scale construction, lack of longitudinal data, and item characteristics are discussed.
No takes yet. Share an insight, caveat, or question.
Matza et al. (2008) conducted a cross-sectional in Asthma, diabetes, and congestive heart failure (n=112). ASK-20 questionnaire was evaluated on Internal consistency and test-retest reliability (Cronbach's alpha 0.76; test-retest reliability 0.80). The ASK-20 questionnaire demonstrated good internal consistency (Cronbach's alpha = 0.76) and test-retest reliability (0.80), with significant concurrent validity against other adherence measures.